LC1D Series AC Contactor | TeSys 3P 9A-95A Motor Control Contactor
LC1D Series AC Contactor | TeSys 3P 9A-95A Motor Control Contactor
The LC1D Series AC Contactor (TeSys) is a high-performance 3-pole contactor designed for motor control and power switching applications. Available in 9A~95A ratings with AC-3 400V capability, it features 1NO/1NC auxiliary contacts and compatible coil voltages (24V/110V/220V). DIN rail-mounted and built to IEC standards, it delivers reliable performance in industrial machinery, HVAC systems, and automation equipment.
The LC1D Series AC Contactor (TeSys) is a high-performance 3-pole contactor designed for motor control and power switching applications. Available in 9A~95A ratings with AC-3 400V capability, it features 1NO/1NC auxiliary contacts and compatible coil voltages (24V/110V/220V). DIN rail-mounted and built to IEC standards, it delivers reliable performance in industrial machinery, HVAC systems, and automation equipment.
1. Product Overview
2. Core Product Features
1. Versatile Current & Voltage Ratings
- Current Range: 9A / 12A / 18A / 25A / 32A / 40A / 50A / 65A / 80A / 95A models, covering light to medium industrial motor loads
- Rated Voltage: 400V AC (AC-3 duty), compatible with standard industrial power grids
- Coil Voltage Options: 24V, 110V, 220V AC/DC coils available to match control system requirements
- Auxiliary Contacts: Standard 1NO + 1NC auxiliary contacts for status feedback and interlocking
2. Reliable Electrical Performance
- AC-3 Rated: Optimized for motor starting and stopping (AC-3 duty), with high breaking capacity for inductive loads
- Silver Alloy Contacts: Low-resistance contacts minimize arcing and ensure long service life
- Low Power Consumption: Energy-efficient coil design reduces power draw while maintaining reliable operation
- High Short-Circuit Withstand: Robust construction withstands fault currents in industrial environments
3. Safety & User-Friendly Design
- TeSys Control Interface: Clear front panel marking for easy coil voltage and status identification
- Modular DIN Rail Mount: Standard 35mm DIN rail mounting for quick, tool-less installation
- Finger-Safe Terminals: Protected terminal design prevents accidental contact during installation and maintenance
- Clear Wiring Markings: Standard terminal labels (L1/L2/L3, T1/T2/T3, A1/A2, NO/NC) simplify wiring
4. Durability & Reliability
- Long Mechanical Life: 10,000,000+ operations for long-term use in high-frequency applications
- Wide Operating Temperature: -25°C to +55°C, suitable for diverse industrial environments
- Compliant with IEC Standards: Manufactured to meet IEC 60947-4-1 requirements for safety and reliability
- Shock & Vibration Resistant: Robust internal components withstand typical industrial vibration conditions
3. Working Conditions
- Ambient Temperature: -25°C to +55°C
- Protection Rating: IP20 (front face), suitable for indoor use in control panels
- Atmospheric Conditions: Air free of corrosive gases, excessive dust, and flammable materials
- Altitude: ≤2000 meters above sea level
- Vibration Resistance: Withstands typical industrial mechanical vibration (10-150Hz, 0.7g)
- Pollution Degree: Pollution Degree 2, suitable for standard industrial environments
4. Technical Specifications
| Model | Rated Current Ie (A) | Motor Power(kW 400V) | Auxiliary Contacts | Weight (kg) | Dimensions W×H×D (mm) |
|---|---|---|---|---|---|
| LC1D09 | 9 | 4 | 1NO+1NC | 0.32 | 45×85×76 |
| LC1D12 | 12 | 5.5 | 1NO+1NC | 0.325 | 45×85×76 |
| LC1D18 | 18 | 7.5 | 1NO+1NC | 0.33 | 45×85×76 |
| LC1D25 | 25 | 11 | 1NO+1NC | 0.37 | 45×85×76 |
| LC1D32 | 32 | 15 | 1NO+1NC | 0.43 | 45×85×76 |
| LC1D40 | 40 | 18.5 | 1NO+1NC | 0.55 | 55×95×85 |
| LC1D50 | 50 | 22 | 1NO+1NC | 0.65 | 55×95×85 |
| LC1D65 | 65 | 30 | 1NO+1NC | 0.75 | 55×95×85 |
| LC1D80 | 80 | 37 | 1NO+1NC | 0.95 | 70×110×95 |
| LC1D95 | 95 | 45 | 1NO+1NC | 1.10 | 70×110×95 |
| Item | Specification |
|---|---|
| Rated Operational Voltage (Ue) | ≤690 V AC, 25~400 Hz |
| Rated Insulation Voltage (Ui) | 690 V (IEC), 600 V (UL/CSA) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Frequency | 50/60 Hz |
| Mechanical Life | Up to 30,000,000 cycles |
| Electrical Life (AC-3 @400V) | Up to 2,000,000 cycles |
| Electrical Life (AC-1 @400V) | Up to 1,400,000 cycles |
| Max Operating Frequency | 3,600 cycles/h |
| Operating Time (20°C) | Closing: 70 ms; Opening: 25 ms |
| Operating Ambient Temperature | -5°C ~ +60°C |
| Storage Temperature | -40°C ~ +70°C |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Protection Grade | IP20 |
5. Typical Applications
- Industrial motor control (pumps, fans, compressors)
- HVAC and refrigeration systems
- Manufacturing line automation equipment
- Commercial building power distribution
- Control panels and PLC-based automation systems
- Renewable energy power distribution systems
- Emergency shutdown and safety circuits
6. Frequently Asked Questions (FAQ)
1. What does “AC-3 rated” mean for this contactor?
2. Can I use this contactor for both AC and DC coil voltages?
3. What is the purpose of the auxiliary contacts (1NO/1NC)?
4. How do I choose the right current rating for my motor?
5. Is this contactor suitable for outdoor use?
6. How do I install the LC1D contactor?
- Mount the contactor on a standard 35mm DIN rail in the control panel.
- Connect the main power lines to the L1/L2/L3 terminals and load lines to T1/T2/T3.
- Connect the control coil voltage to the A1/A2 terminals, matching the coil voltage rating.
- Wire the auxiliary contacts (NO/NC) as needed for status feedback or interlocking.
- Test the contactor by applying control voltage to verify proper operation.
7. Technical documentation and support
Download the full datasheet for detailed specifications, wiring diagrams and trip coordination guides.
Please contact our technical team for custom configuration or OEM/ODM solutions for your project.
Request a quote with details about your project for volume pricing, lead times, and compliance certifications.
1. Product Overview
2. Core Product Features
1. Versatile Current & Voltage Ratings
- Current Range: 9A / 12A / 18A / 25A / 32A / 40A / 50A / 65A / 80A / 95A models, covering light to medium industrial motor loads
- Rated Voltage: 400V AC (AC-3 duty), compatible with standard industrial power grids
- Coil Voltage Options: 24V, 110V, 220V AC/DC coils available to match control system requirements
- Auxiliary Contacts: Standard 1NO + 1NC auxiliary contacts for status feedback and interlocking
2. Reliable Electrical Performance
- AC-3 Rated: Optimized for motor starting and stopping (AC-3 duty), with high breaking capacity for inductive loads
- Silver Alloy Contacts: Low-resistance contacts minimize arcing and ensure long service life
- Low Power Consumption: Energy-efficient coil design reduces power draw while maintaining reliable operation
- High Short-Circuit Withstand: Robust construction withstands fault currents in industrial environments
3. Safety & User-Friendly Design
- TeSys Control Interface: Clear front panel marking for easy coil voltage and status identification
- Modular DIN Rail Mount: Standard 35mm DIN rail mounting for quick, tool-less installation
- Finger-Safe Terminals: Protected terminal design prevents accidental contact during installation and maintenance
- Clear Wiring Markings: Standard terminal labels (L1/L2/L3, T1/T2/T3, A1/A2, NO/NC) simplify wiring
4. Durability & Reliability
- Long Mechanical Life: 10,000,000+ operations for long-term use in high-frequency applications
- Wide Operating Temperature: -25°C to +55°C, suitable for diverse industrial environments
- Compliant with IEC Standards: Manufactured to meet IEC 60947-4-1 requirements for safety and reliability
- Shock & Vibration Resistant: Robust internal components withstand typical industrial vibration conditions
3. Working Conditions
- Ambient Temperature: -25°C to +55°C
- Protection Rating: IP20 (front face), suitable for indoor use in control panels
- Atmospheric Conditions: Air free of corrosive gases, excessive dust, and flammable materials
- Altitude: ≤2000 meters above sea level
- Vibration Resistance: Withstands typical industrial mechanical vibration (10-150Hz, 0.7g)
- Pollution Degree: Pollution Degree 2, suitable for standard industrial environments
4. Technical Specifications
| Model | Rated Current Ie (A) | Motor Power(kW 400V) | Auxiliary Contacts | Weight (kg) | Dimensions W×H×D (mm) |
|---|---|---|---|---|---|
| LC1D09 | 9 | 4 | 1NO+1NC | 0.32 | 45×85×76 |
| LC1D12 | 12 | 5.5 | 1NO+1NC | 0.325 | 45×85×76 |
| LC1D18 | 18 | 7.5 | 1NO+1NC | 0.33 | 45×85×76 |
| LC1D25 | 25 | 11 | 1NO+1NC | 0.37 | 45×85×76 |
| LC1D32 | 32 | 15 | 1NO+1NC | 0.43 | 45×85×76 |
| LC1D40 | 40 | 18.5 | 1NO+1NC | 0.55 | 55×95×85 |
| LC1D50 | 50 | 22 | 1NO+1NC | 0.65 | 55×95×85 |
| LC1D65 | 65 | 30 | 1NO+1NC | 0.75 | 55×95×85 |
| LC1D80 | 80 | 37 | 1NO+1NC | 0.95 | 70×110×95 |
| LC1D95 | 95 | 45 | 1NO+1NC | 1.10 | 70×110×95 |
| Item | Specification |
|---|---|
| Rated Operational Voltage (Ue) | ≤690 V AC, 25~400 Hz |
| Rated Insulation Voltage (Ui) | 690 V (IEC), 600 V (UL/CSA) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Frequency | 50/60 Hz |
| Mechanical Life | Up to 30,000,000 cycles |
| Electrical Life (AC-3 @400V) | Up to 2,000,000 cycles |
| Electrical Life (AC-1 @400V) | Up to 1,400,000 cycles |
| Max Operating Frequency | 3,600 cycles/h |
| Operating Time (20°C) | Closing: 70 ms; Opening: 25 ms |
| Operating Ambient Temperature | -5°C ~ +60°C |
| Storage Temperature | -40°C ~ +70°C |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Protection Grade | IP20 |
5. Typical Applications
- Industrial motor control (pumps, fans, compressors)
- HVAC and refrigeration systems
- Manufacturing line automation equipment
- Commercial building power distribution
- Control panels and PLC-based automation systems
- Renewable energy power distribution systems
- Emergency shutdown and safety circuits
6. Frequently Asked Questions (FAQ)
1. What does “AC-3 rated” mean for this contactor?
2. Can I use this contactor for both AC and DC coil voltages?
3. What is the purpose of the auxiliary contacts (1NO/1NC)?
4. How do I choose the right current rating for my motor?
5. Is this contactor suitable for outdoor use?
6. How do I install the LC1D contactor?
- Mount the contactor on a standard 35mm DIN rail in the control panel.
- Connect the main power lines to the L1/L2/L3 terminals and load lines to T1/T2/T3.
- Connect the control coil voltage to the A1/A2 terminals, matching the coil voltage rating.
- Wire the auxiliary contacts (NO/NC) as needed for status feedback or interlocking.
- Test the contactor by applying control voltage to verify proper operation.
7. Technical documentation and support
Download the full datasheet for detailed specifications, wiring diagrams and trip coordination guides.
Please contact our technical team for custom configuration or OEM/ODM solutions for your project.
Request a quote with details about your project for volume pricing, lead times, and compliance certifications.
Related Products
Contact Us
Have questions about our products or services? Our team is here to help you with any inquiries.