LMM1E 3P/4P 63-1250A Electronic MCCB Adjustable Circuit Breaker

LMM1E 3P/4P 63-1250A Electronic MCCB Adjustable Circuit Breaker

Standard: IEC60947-2
Model: LMM1E
Poles: 3P,4P
Frame size: 160,250,400,630,800,1250,1600
Rated operational voltage: 400/415/690V
Rated insulation voltage: 1000V
Trip unit type: electronic type
Breaking capacity code: L,M,H
Installation method: Fixed type; plug-in type
Adjustable Tripping Setting: Ir, Isd, Ii, tR, tsd, Ip
Ambient Temperature: -25…+40 ºC
Certificate: CE, CB
Available in black or white covers

LMM1 MCCB Manual

Standard: IEC60947-2
Model: LMM1E
Poles: 3P,4P
Frame size: 160,250,400,630,800,1250,1600
Rated operational voltage: 400/415/690V
Rated insulation voltage: 1000V
Trip unit type: electronic type
Breaking capacity code: L,M,H
Installation method: Fixed type; plug-in type
Adjustable Tripping Setting: Ir, Isd, Ii, tR, tsd, Ip
Ambient Temperature: -25…+40 ºC
Certificate: CE, CB
Available in black or white covers

LMM1 MCCB Manual

1. Product Overview

The LVMA  63-1250A Electronic MCCB is a high-performance, three-phase molded case circuit breaker equipped with an advanced electronic trip unit. Designed for heavy-duty industrial and commercial power distribution systems, this MCCB offers fully adjustable overload, short-time delay, and instantaneous protection settings, providing precise and flexible protection tailored to the needs of large-scale facilities. Built to handle high currents and severe fault conditions, it is ideal for use as a main breaker in distribution panels, generator switchgear, and industrial machinery control centers.

2. Key Specifications

Parameter Details
Model LVMA 3P Electronic MCCB
Poles 3P / 4P
Rated Operational Voltage (Ue) AC 400V / 50Hz
Rated Insulation Voltage (Ui) AC 690V
Rated Impulse Withstand Voltage (Uimp) 8kV
Rated Current (In) 63A-1250A(adjustable via electronic trip)
Ultimate Breaking Capacity (Icu) 50kA / 65kA (at 400V)
Service Breaking Capacity (Ics) 50%~100% of Icu
Trip Unit Type Electronic (adjustable)
Protection Functions Overload (long-time delay), Short-circuit (short-time delay), Instantaneous, Ground fault (optional)
Mounting Type Panel mount
Enclosure Rating IP20 (front face)
Compliance Standards IEC 60947-2, GB/T 14048.2
Operating Temperature -10°C ~ +60°C
Mechanical Life ≥8,000 operations
Electrical Life ≥1,500 operations at rated load

3. Core Features

Adjustable Electronic Trip Unit: Multiple rotary dials allow precise tuning of long-time (overload), short-time, and instantaneous trip settings for custom protection coordination.

High-Current Capacity: Rated at 630A with high breaking capacity options, suitable for main distribution circuits in large facilities.

Advanced Protection Modes: Supports selective coordination with upstream/downstream devices to prevent unnecessary outages during faults.

Clear Status Indicators: LED indicators show power, trip, and fault status for quick diagnostics and maintenance checks.

Robust Molded Case: Flame-retardant, impact-resistant plastic housing (UL94 V-0) provides excellent durability and electrical insulation in harsh environments.

High Breaking Capacity: With up to 65kA Icu at 400V, it provides reliable protection against severe short-circuit faults.

Large Terminal Connections: Oversized terminals accommodate high-current cables, ensuring secure and low-resistance connections.

Optional Ground Fault Protection: Available with integrated ground fault protection for enhanced safety in sensitive applications.

4. Applications

  • Main distribution panels for industrial facilities and commercial buildings
  • Generator and backup power system main breakers
  • Three-phase motor control centers and heavy machinery
  • Mining, manufacturing, and heavy-duty industrial power systems
  • Solar and wind power plant AC-side distribution
  • Data center and large-scale commercial power distribution

5. Why Choose LVMA Electronic MCCB?

  • Precise & Flexible Protection: Electronic trip unit allows custom trip settings, enabling selective coordination and tailored protection for complex systems.
  • High-Current Reliability: 63-1250A rating and high breaking capacity make it suitable for the most demanding industrial power distribution applications.
  • Advanced Diagnostics: LED status indicators simplify troubleshooting and maintenance, reducing downtime.
  • Durable Construction: Flame-retardant housing and high-quality components ensure long-term performance in harsh environments.
  • Compliant & Safe: Meets IEC 60947-2 standards, providing peace of mind for safety and regulatory compliance.
  • Cost-Effective Long-Term Solution: Adjustable settings eliminate the need for frequent device replacement as system requirements change.

6. Technical Documents & Support

  • Download the full datasheet for detailed specifications, wiring diagrams, and trip coordination guidelines.
  • Contact our engineering team for custom trip settings, pole configurations, or OEM/ODM solutions for large-scale projects.
  • Request a quote with your project details for bulk pricing, lead times, and compliance certifications.

1. Product Overview

The LVMA  63-1250A Electronic MCCB is a high-performance, three-phase molded case circuit breaker equipped with an advanced electronic trip unit. Designed for heavy-duty industrial and commercial power distribution systems, this MCCB offers fully adjustable overload, short-time delay, and instantaneous protection settings, providing precise and flexible protection tailored to the needs of large-scale facilities. Built to handle high currents and severe fault conditions, it is ideal for use as a main breaker in distribution panels, generator switchgear, and industrial machinery control centers.

2. Key Specifications

Parameter Details
Model LVMA 3P Electronic MCCB
Poles 3P / 4P
Rated Operational Voltage (Ue) AC 400V / 50Hz
Rated Insulation Voltage (Ui) AC 690V
Rated Impulse Withstand Voltage (Uimp) 8kV
Rated Current (In) 63A-1250A(adjustable via electronic trip)
Ultimate Breaking Capacity (Icu) 50kA / 65kA (at 400V)
Service Breaking Capacity (Ics) 50%~100% of Icu
Trip Unit Type Electronic (adjustable)
Protection Functions Overload (long-time delay), Short-circuit (short-time delay), Instantaneous, Ground fault (optional)
Mounting Type Panel mount
Enclosure Rating IP20 (front face)
Compliance Standards IEC 60947-2, GB/T 14048.2
Operating Temperature -10°C ~ +60°C
Mechanical Life ≥8,000 operations
Electrical Life ≥1,500 operations at rated load

3. Core Features

Adjustable Electronic Trip Unit: Multiple rotary dials allow precise tuning of long-time (overload), short-time, and instantaneous trip settings for custom protection coordination.

High-Current Capacity: Rated at 630A with high breaking capacity options, suitable for main distribution circuits in large facilities.

Advanced Protection Modes: Supports selective coordination with upstream/downstream devices to prevent unnecessary outages during faults.

Clear Status Indicators: LED indicators show power, trip, and fault status for quick diagnostics and maintenance checks.

Robust Molded Case: Flame-retardant, impact-resistant plastic housing (UL94 V-0) provides excellent durability and electrical insulation in harsh environments.

High Breaking Capacity: With up to 65kA Icu at 400V, it provides reliable protection against severe short-circuit faults.

Large Terminal Connections: Oversized terminals accommodate high-current cables, ensuring secure and low-resistance connections.

Optional Ground Fault Protection: Available with integrated ground fault protection for enhanced safety in sensitive applications.

4. Applications

  • Main distribution panels for industrial facilities and commercial buildings
  • Generator and backup power system main breakers
  • Three-phase motor control centers and heavy machinery
  • Mining, manufacturing, and heavy-duty industrial power systems
  • Solar and wind power plant AC-side distribution
  • Data center and large-scale commercial power distribution

5. Why Choose LVMA Electronic MCCB?

  • Precise & Flexible Protection: Electronic trip unit allows custom trip settings, enabling selective coordination and tailored protection for complex systems.
  • High-Current Reliability: 63-1250A rating and high breaking capacity make it suitable for the most demanding industrial power distribution applications.
  • Advanced Diagnostics: LED status indicators simplify troubleshooting and maintenance, reducing downtime.
  • Durable Construction: Flame-retardant housing and high-quality components ensure long-term performance in harsh environments.
  • Compliant & Safe: Meets IEC 60947-2 standards, providing peace of mind for safety and regulatory compliance.
  • Cost-Effective Long-Term Solution: Adjustable settings eliminate the need for frequent device replacement as system requirements change.

6. Technical Documents & Support

  • Download the full datasheet for detailed specifications, wiring diagrams, and trip coordination guidelines.
  • Contact our engineering team for custom trip settings, pole configurations, or OEM/ODM solutions for large-scale projects.
  • Request a quote with your project details for bulk pricing, lead times, and compliance certifications.