LMM1EL Auto Reclosing Circuit Breaker

LMM1EL Auto Reclosing Circuit Breaker

It is an intelligent power equipment that integrates protection, monitoring and control. When the line trips due to a fault, it can automatically start the recovery program and try to close after a preset delay to achieve automatic recovery from instantaneous faults.

Model name:LMM1EL
Rated current:125、250、400、630、800
Setting current range:(0.4~1)In
Poles:3P(220V)、3P+N、4P
Rated insulation voltage Ui (V):AC 1000V
Rated impulse withstand voltage Uimp (kV):12kV
Rated working voltage Ue(V): AC 400V 50/60Hz

It is an intelligent power equipment that integrates protection, monitoring and control. When the line trips due to a fault, it can automatically start the recovery program and try to close after a preset delay to achieve automatic recovery from instantaneous faults.

Model name:LMM1EL
Rated current:125、250、400、630、800
Setting current range:(0.4~1)In
Poles:3P(220V)、3P+N、4P
Rated insulation voltage Ui (V):AC 1000V
Rated impulse withstand voltage Uimp (kV):12kV
Rated working voltage Ue(V): AC 400V 50/60Hz

The LMM1EL series reclosing current operated circuit breaker(hereinafterreferred toas circuit breaker)is mainly suitable for distribution networks with frequency of AC 50/60Hz and rated working voltage ofAC400V Used in three-phasefour-wire power supply andconsumption system with neutral point directly grounded.It has functions such as overload, short circuit, phase loss, overvoltage, undervoltage.residual current action protection, etc. lt can protect circuit and electrical equipmenfrom damage, and also provide protection for possible grounding fault and indirectpersonal contact in circuit.The product complies with IEC 60947-2 standard.

Product feature

 Multiple functions

It has protection functions such as residual current, overcurrent, short circuit, etcas well as practical functions such as automatic reclosing, residual current display, realtime load current display, action status indication and trp data display. The product alsohas functions such as pluggable lightning protection module, four remote functions and special adapter.

 Small volume

The combination of electric operating mechanism and air circuit breaker has been transformed into an integrated type, with reduced installation location and wiring.The operation method with configurable function characteristic can set the required functions such as action current,breaking time and main circuit current according to the actual situation.

intelligence

The intelligent control circuit composed of single chip microprocessor can set and display load current, monitor the cause of fault trip, display fault parameters during trip,and query the total number of various fault trips.

Communicability (when this function is required during ordering)

The communication type leakage circuit breaker can record and query detailed date such as the phase sequence that causes the trip, cause and trip time, and has the function of historical data recording; the communication series product adopts RS-485 communication port and have multiple communication protocols to choose from.it can establish communication function with intelligent distribution transformer terminal, upper computer, etc., and achieve remote parameter adjustment, information query and fault parameter download.

Main technical parameter

Parameter ItemLMM1EL-125LMM1EL-250LMM1EL-400LMM1EL-630LMM1EL-800
Frame current In (A)125250400630800
Overload long delay setting range IR (A)(0.4~1)In
Rated residual operating current I△n (mA)30 (non delay type only); 50/100/150/200/300/500/900/1000/OFF graded adjustment delay type, automatic tracking
Ultimate non driving time (s)0.06 / 0.1 / 0.2 optional settings
Number of poles3P+N; 4P
Rated insulation voltage Ui (V)AC 1000
Rated impulse withstand voltage Uimp (kV)12kV
Rated working voltage Ue (V)AC 400 50/60Hz
Rated ultimate short-circuit breaking capacity Icu (kA)M50/H85M50/H85M65/H85M65/H8565
Rated service short-circuit breaking capacity Ics (kA)M35/H65M35/H65M50/H65M50/H65100
Rated short time withstand current Icw5kA/1S5kA/1S10kA/1S10kA/1S10kA/1S
Selective categoryCategory BCategory BCategory BCategory BCategory B
Rated residual short-circuit making and breaking capacity I△m (kA)25% Icu
Reclosing interval time (s)20~60 (manual closing is not limited by time interval)

Overload Long Delay Parameter Setting Table

ParameterFrame currentSet valueFactory set value
Action set value Ir112550A~125A adjustable125A
250100A~250A adjustable250A
400160A~400A adjustable400A
630252A~630A adjustable630A
800320A~800A adjustable800A
Delay time set value tL3–18s3s

Installation dimension

SpecificationOutline dimensionInstallation dimensionExternal copper plate dimensionInstallation screw dimension
WLHABDC
LMM1EL-125122220122199603016φ4 × 45
LMM1EL-250142240135201703522φ4 × 45
LMM1EL-400(630)195335177272964830φ6 × 70
LMM1EL-8002403551872851165840φ6 × 70

The LMM1EL series reclosing current operated circuit breaker(hereinafterreferred toas circuit breaker)is mainly suitable for distribution networks with frequency of AC 50/60Hz and rated working voltage ofAC400V Used in three-phasefour-wire power supply andconsumption system with neutral point directly grounded.It has functions such as overload, short circuit, phase loss, overvoltage, undervoltage.residual current action protection, etc. lt can protect circuit and electrical equipmenfrom damage, and also provide protection for possible grounding fault and indirectpersonal contact in circuit.The product complies with IEC 60947-2 standard.

Product feature

 Multiple functions

It has protection functions such as residual current, overcurrent, short circuit, etcas well as practical functions such as automatic reclosing, residual current display, realtime load current display, action status indication and trp data display. The product alsohas functions such as pluggable lightning protection module, four remote functions and special adapter.

 Small volume

The combination of electric operating mechanism and air circuit breaker has been transformed into an integrated type, with reduced installation location and wiring.The operation method with configurable function characteristic can set the required functions such as action current,breaking time and main circuit current according to the actual situation.

intelligence

The intelligent control circuit composed of single chip microprocessor can set and display load current, monitor the cause of fault trip, display fault parameters during trip,and query the total number of various fault trips.

Communicability (when this function is required during ordering)

The communication type leakage circuit breaker can record and query detailed date such as the phase sequence that causes the trip, cause and trip time, and has the function of historical data recording; the communication series product adopts RS-485 communication port and have multiple communication protocols to choose from.it can establish communication function with intelligent distribution transformer terminal, upper computer, etc., and achieve remote parameter adjustment, information query and fault parameter download.

Main technical parameter

Parameter ItemLMM1EL-125LMM1EL-250LMM1EL-400LMM1EL-630LMM1EL-800
Frame current In (A)125250400630800
Overload long delay setting range IR (A)(0.4~1)In
Rated residual operating current I△n (mA)30 (non delay type only); 50/100/150/200/300/500/900/1000/OFF graded adjustment delay type, automatic tracking
Ultimate non driving time (s)0.06 / 0.1 / 0.2 optional settings
Number of poles3P+N; 4P
Rated insulation voltage Ui (V)AC 1000
Rated impulse withstand voltage Uimp (kV)12kV
Rated working voltage Ue (V)AC 400 50/60Hz
Rated ultimate short-circuit breaking capacity Icu (kA)M50/H85M50/H85M65/H85M65/H8565
Rated service short-circuit breaking capacity Ics (kA)M35/H65M35/H65M50/H65M50/H65100
Rated short time withstand current Icw5kA/1S5kA/1S10kA/1S10kA/1S10kA/1S
Selective categoryCategory BCategory BCategory BCategory BCategory B
Rated residual short-circuit making and breaking capacity I△m (kA)25% Icu
Reclosing interval time (s)20~60 (manual closing is not limited by time interval)

Overload Long Delay Parameter Setting Table

ParameterFrame currentSet valueFactory set value
Action set value Ir112550A~125A adjustable125A
250100A~250A adjustable250A
400160A~400A adjustable400A
630252A~630A adjustable630A
800320A~800A adjustable800A
Delay time set value tL3–18s3s

Installation dimension

SpecificationOutline dimensionInstallation dimensionExternal copper plate dimensionInstallation screw dimension
WLHABDC
LMM1EL-125122220122199603016φ4 × 45
LMM1EL-250142240135201703522φ4 × 45
LMM1EL-400(630)195335177272964830φ6 × 70
LMM1EL-8002403551872851165840φ6 × 70

Data Download

LVMA low voltage selection manual

Related Products

Contact Us

Have questions about our products or services? Our team is here to help you with any inquiries.

Email Address

Your Name

Your phone

Message

Contact Information

Follow Us