- Model name: LM47-63
- Rated current:1,2,3,4,5,6,8,10,13,16,20,25,32,40,50,63A
- Rated voltage :230/400V
- Poles:1P,2P,3P,4P
- Rated Breaking capacity:4500A
- Standard:IEC/EN 60898-1
Miniature Circuit Breaker (MCB) is the core component for Circuit protection and on-off control in low-voltage distribution systems, which is widely used in homes, commercial buildings and small industrial scenarios.
- Model name: LM47-63
- Rated current:1,2,3,4,5,6,8,10,13,16,20,25,32,40,50,63A
- Rated voltage :230/400V
- Poles:1P,2P,3P,4P
- Rated Breaking capacity:4500A
- Standard:IEC/EN 60898-1
1. Product Overview
2. Core Product Features
1. Flexible Pole Configurations for Every Application
- 1P: Ideal for single-phase lighting and small power circuits
- 2P: Suitable for single-phase main circuits and equipment requiring neutral protection
- 3P: Perfect for three-phase industrial machinery and motor control circuits
- 4P: Designed for three-phase systems with neutral, ensuring comprehensive protection for commercial and industrial distribution panels
2. Robust Electrical Performance
- Rated Current: C63 (63A), supporting high-power loads up to 13.8kW (230V) or 43.7kW (400V three-phase)
- Breaking Capacity: 4500A interrupting capacity, quickly isolating short-circuit faults to prevent equipment damage and fire hazards
- C-Curve Trip Characteristic: Optimized for general-purpose circuits, with a trip response between 5–10 times rated current to accommodate moderate inrush currents from motors, lighting, and appliances without nuisance tripping
- Voltage Compatibility: Rated for 230V (1P) / 400V (2P/3P/4P) AC systems at 50Hz, suitable for global low-voltage power grids
3. Premium Safety & Compliance
- Certified to International Standards: Fully compliant with IEC60898-1 (international) and GB/T10963.1 (Chinese national) standards, with 3C certification for quality assurance
- Advanced Arc Extinguishing System: High-efficiency arc-quenching mechanism safely contains and extinguishes arcs during fault conditions, extending the breaker’s service life and preventing electrical fires
- Clear Status Indication: Ergonomic green toggle with visible “ON/OFF” markings for quick circuit status identification, even in low-light environments
- Shock-Resistant Construction: High-grade flame-retardant thermoplastic housing provides excellent insulation and resistance to impact, heat, and aging
4. User-Friendly Installation & Maintenance
- Standard DIN Rail Mounting: Compatible with 35mm DIN rails, enabling quick, tool-less installation in distribution panels
- Universal Wiring Compatibility: Top/bottom terminal design supports flexible wiring configurations for both incoming and outgoing circuits
- Modular Design: Compact form factor saves valuable panel space, with uniform dimensions across all pole counts for easy system expansion
- Easy Operation: Smooth, ergonomic toggle allows effortless manual tripping and resetting for maintenance and emergency use
3. Key Advantages Over Competitors
| Feature | LVMA LM47-63 MCB | Generic Budget MCBs | Mid-Range Competitor MCBs |
|---|---|---|---|
| Breaking Capacity | 4500A (IEC/GB certified) | Often uncertified, <2000A | 3000A (some non-certified) |
| Trip Consistency | Stable C-curve response, minimal nuisance tripping | Inconsistent trip characteristics, frequent false trips | Moderate consistency, occasional tripping issues |
| Housing Material | Flame-retardant, high-temperature resistant thermoplastic | Low-grade plastic, prone to melting under heat | Standard flame-retardant plastic |
| Certification | 3C, IEC60898-1, GB/T10963.1 | No third-party certification | Partial certification (IEC only) |
| Installation Flexibility | Universal top/bottom terminals, full pole range | Limited pole options, fixed terminal orientation | Standard terminals, limited pole configurations |
| Durability | 10,000+ mechanical operations, 4,000+ electrical operations | <5,000 operations, short service life | 8,000+ mechanical operations, 3,000+ electrical operations |
4. Technical Specifications
| Parameter | Specification |
|---|---|
| Model | LM47-63 |
| Rated Current | 63A (C63) |
| Poles | 1P / 2P / 3P / 4P |
| Rated Voltage | 230V AC (1P) / 400V AC (2P/3P/4P) |
| Frequency | 50Hz |
| Breaking Capacity | 4500A |
| Trip Curve | B/C/D-Curve |
| Compliance Standards | IEC60898-1, GB/T10963.1, 3C Certified |
| Mounting Type | 35mm DIN Rail |
| Operating Temperature | -25°C to +40°C |
| Mechanical Endurance | ≥10,000 operations |
| Electrical Endurance | ≥4,000 operations |
| Housing Material | Flame-retardant thermoplastic |
| Terminal Type | Screw-type, copper conductor compatible |
5. Typical Applications
- Residential distribution boards (whole-house protection, high-power appliance circuits)
- Commercial building lighting and power distribution panels
- Industrial machinery control circuits and motor protection
- HVAC systems, elevators, and office equipment circuits
- Small commercial and retail power distribution systems
- Solar and renewable energy low-voltage distribution systems
6. Safety & Reliability Assurance
7.Tripping Characteristic (IEC60898-1)

8.Overall and Installation Dimension(mm)

9. FAQ
Q1: What is the difference between MCB miniature circuit breaker and ordinary air switch?
Q2: How to choose the right MCB current specification?
Q3: What are the B/C/D trip curves used for?
Q4: Do you support bulk wholesale and customized services?
10. Technical documentation and support
Download the full datasheet for detailed specifications, wiring diagrams and trip coordination guides.
Please contact our technical team for custom configuration or OEM/ODM solutions for your project.
Request a quote with details about your project for volume pricing, lead times, and compliance certifications.
1. Product Overview
2. Core Product Features
1. Flexible Pole Configurations for Every Application
- 1P: Ideal for single-phase lighting and small power circuits
- 2P: Suitable for single-phase main circuits and equipment requiring neutral protection
- 3P: Perfect for three-phase industrial machinery and motor control circuits
- 4P: Designed for three-phase systems with neutral, ensuring comprehensive protection for commercial and industrial distribution panels
2. Robust Electrical Performance
- Rated Current: C63 (63A), supporting high-power loads up to 13.8kW (230V) or 43.7kW (400V three-phase)
- Breaking Capacity: 4500A interrupting capacity, quickly isolating short-circuit faults to prevent equipment damage and fire hazards
- C-Curve Trip Characteristic: Optimized for general-purpose circuits, with a trip response between 5–10 times rated current to accommodate moderate inrush currents from motors, lighting, and appliances without nuisance tripping
- Voltage Compatibility: Rated for 230V (1P) / 400V (2P/3P/4P) AC systems at 50Hz, suitable for global low-voltage power grids
3. Premium Safety & Compliance
- Certified to International Standards: Fully compliant with IEC60898-1 (international) and GB/T10963.1 (Chinese national) standards, with 3C certification for quality assurance
- Advanced Arc Extinguishing System: High-efficiency arc-quenching mechanism safely contains and extinguishes arcs during fault conditions, extending the breaker’s service life and preventing electrical fires
- Clear Status Indication: Ergonomic green toggle with visible “ON/OFF” markings for quick circuit status identification, even in low-light environments
- Shock-Resistant Construction: High-grade flame-retardant thermoplastic housing provides excellent insulation and resistance to impact, heat, and aging
4. User-Friendly Installation & Maintenance
- Standard DIN Rail Mounting: Compatible with 35mm DIN rails, enabling quick, tool-less installation in distribution panels
- Universal Wiring Compatibility: Top/bottom terminal design supports flexible wiring configurations for both incoming and outgoing circuits
- Modular Design: Compact form factor saves valuable panel space, with uniform dimensions across all pole counts for easy system expansion
- Easy Operation: Smooth, ergonomic toggle allows effortless manual tripping and resetting for maintenance and emergency use
3. Key Advantages Over Competitors
| Feature | LVMA LM47-63 MCB | Generic Budget MCBs | Mid-Range Competitor MCBs |
|---|---|---|---|
| Breaking Capacity | 4500A (IEC/GB certified) | Often uncertified, <2000A | 3000A (some non-certified) |
| Trip Consistency | Stable C-curve response, minimal nuisance tripping | Inconsistent trip characteristics, frequent false trips | Moderate consistency, occasional tripping issues |
| Housing Material | Flame-retardant, high-temperature resistant thermoplastic | Low-grade plastic, prone to melting under heat | Standard flame-retardant plastic |
| Certification | 3C, IEC60898-1, GB/T10963.1 | No third-party certification | Partial certification (IEC only) |
| Installation Flexibility | Universal top/bottom terminals, full pole range | Limited pole options, fixed terminal orientation | Standard terminals, limited pole configurations |
| Durability | 10,000+ mechanical operations, 4,000+ electrical operations | <5,000 operations, short service life | 8,000+ mechanical operations, 3,000+ electrical operations |
4. Technical Specifications
| Parameter | Specification |
|---|---|
| Model | LM47-63 |
| Rated Current | 63A (C63) |
| Poles | 1P / 2P / 3P / 4P |
| Rated Voltage | 230V AC (1P) / 400V AC (2P/3P/4P) |
| Frequency | 50Hz |
| Breaking Capacity | 4500A |
| Trip Curve | B/C/D-Curve |
| Compliance Standards | IEC60898-1, GB/T10963.1, 3C Certified |
| Mounting Type | 35mm DIN Rail |
| Operating Temperature | -25°C to +40°C |
| Mechanical Endurance | ≥10,000 operations |
| Electrical Endurance | ≥4,000 operations |
| Housing Material | Flame-retardant thermoplastic |
| Terminal Type | Screw-type, copper conductor compatible |
5. Typical Applications
- Residential distribution boards (whole-house protection, high-power appliance circuits)
- Commercial building lighting and power distribution panels
- Industrial machinery control circuits and motor protection
- HVAC systems, elevators, and office equipment circuits
- Small commercial and retail power distribution systems
- Solar and renewable energy low-voltage distribution systems
6. Safety & Reliability Assurance
7.Tripping Characteristic (IEC60898-1)

8.Overall and Installation Dimension(mm)

9. FAQ
Q1: What is the difference between MCB miniature circuit breaker and ordinary air switch?
Q2: How to choose the right MCB current specification?
Q3: What are the B/C/D trip curves used for?
Q4: Do you support bulk wholesale and customized services?
10. Technical documentation and support
Download the full datasheet for detailed specifications, wiring diagrams and trip coordination guides.
Please contact our technical team for custom configuration or OEM/ODM solutions for your project.
Request a quote with details about your project for volume pricing, lead times, and compliance certifications.
Related Products
Contact Us
Have questions about our products or services? Our team is here to help you with any inquiries.