LMB1-63B Type B RCCB 63A 30mA 10kA 1P+N 3P+N

LMB1-63B Type B RCCB 63A 30mA 10kA 1P+N 3P+N

Type B RCBO 1P+N, 63A, 30mA, 10kA breaking capacity. It detects AC, pulsating DC and smooth DC leakage currents, integrating residual current, overload and short-circuit protection in one compact DIN rail module. EN61008-1 & EN62423 compliant, CE certified, specially designed for EV chargers, solar PV inverters, energy storage and VFD systems.

Type B RCBO 1P+N, 63A, 30mA, 10kA breaking capacity. It detects AC, pulsating DC and smooth DC leakage currents, integrating residual current, overload and short-circuit protection in one compact DIN rail module. EN61008-1 & EN62423 compliant, CE certified, specially designed for EV chargers, solar PV inverters, energy storage and VFD systems.

The LMB1-63B is a high-performance Type B RCBO that combines MCB overcurrent protection and RCD earth leakage protection in a single 1P+N modular unit. Unlike ordinary Type A or AC RCBOs, Type B can reliably detect smooth DC residual faults, which is critical for modern power electronic circuits. It is the ideal safety solution for EV charging stations, solar inverters, battery energy storage systems, heat pumps and variable frequency drives, where DC leakage may occur and standard RCDs could fail to trip and lose protection.

Core Advantages & Key Benefits

✅ Full Type B Sensing Capability Detects AC, pulsating DC and smooth DC residual currents. Avoids the risk of “blinding” common Type A RCDs caused by DC leakage from inverters and EV chargers. Fully meets the safety requirements for EV and solar installations.

✅ 10kA High Breaking Capacity Icn=10000A high short-circuit breaking capacity, stronger fault tolerance, stable performance under sudden short-circuit impact, suitable for commercial and high-demand power distribution systems.

✅ All-in-One 3-in-1 Protection One device provides earth leakage protection, overload protection and short-circuit protection. Saves space inside distribution boxes, reduces wiring points and lowers installation cost compared to separate MCB + RCD combination.

✅ Compact 1P+N Single Module Design Standard 35mm DIN rail mounting, narrow 1-module width. It maximizes available space in consumer units, perfect for compact distribution panels in residential and commercial projects.

✅ Strict International Standards & CE Approval Manufactured and tested to EN61008-1 and EN62423, CE marked. Fully accepted for EU export, overseas electrical projects and certification audit requirements.

✅ Built-in Monthly Test Button Easy regular function test. Electricians can verify the residual current protection function with one press to ensure long-term reliable safety.

✅ Robust & Stable Performance High-quality flame-retardant housing, reliable internal electromagnetic trip mechanism, long mechanical and electrical service life, low false tripping rate under normal working conditions.

Technical Specifications

ItemParameter
ModelLMB1-63B
BrandLVMA
Product TypeType B RCCB
Pole1P+N / 3P+N
Rated Current (In)63A
Rated Residual Operating Current (IΔn)30mA
Rated Voltage230/240V AC
Frequency50/60Hz
Rated Breaking Capacity10kA
Compliance StandardsEN61008-1, EN62423
CertificateCE
Mounting35mm DIN Rail

Typical Applications

  • EV charging circuits / Mode 3 EV charging points
  • Solar PV inverter & battery energy storage systems
  • Variable frequency drives (VFD), frequency converters
  • Heat pumps and inverter air-conditioning equipment
  • Modern residential distribution boards
  • Commercial buildings, workshops and automation equipment with DC leakage risk

Important Notes

  • Press the TEST button every month to confirm the residual current protection works normally.
  • Type A / AC RCBO cannot replace Type B for EV and solar circuits, as they cannot detect smooth DC leakage faults.
  • Installation must be completed by a qualified professional electrician in accordance with local wiring regulations.

FAQ Section

Q: What is the difference between Type B RCBO and Type A RCBO? A: Type B RCBO can detect AC, pulsating DC and smooth DC leakage currents. Type A only detects AC and pulsating DC. For EV chargers and solar inverters, smooth DC leakage may occur, so Type B is mandatory for reliable protection.

Q: Is this LVMA LMB1-63B suitable for EV charger installation? A: Yes, this Type B RCBO is widely used for EV charging point circuits and meets the protection requirements for DC leakage faults in charging systems.

Q: What does 10kA breaking capacity mean? A: 10kA means the RCBO can safely interrupt short-circuit current up to 10000A, offering higher reliability for commercial circuits than standard 6kA models.

Q: Can this RCBO be used for solar inverter output? A: Yes, it is a preferred protective device for the AC side of transformerless solar inverters and energy storage systems.

The LMB1-63B is a high-performance Type B RCBO that combines MCB overcurrent protection and RCD earth leakage protection in a single 1P+N modular unit. Unlike ordinary Type A or AC RCBOs, Type B can reliably detect smooth DC residual faults, which is critical for modern power electronic circuits. It is the ideal safety solution for EV charging stations, solar inverters, battery energy storage systems, heat pumps and variable frequency drives, where DC leakage may occur and standard RCDs could fail to trip and lose protection.

Core Advantages & Key Benefits

✅ Full Type B Sensing Capability Detects AC, pulsating DC and smooth DC residual currents. Avoids the risk of “blinding” common Type A RCDs caused by DC leakage from inverters and EV chargers. Fully meets the safety requirements for EV and solar installations.

✅ 10kA High Breaking Capacity Icn=10000A high short-circuit breaking capacity, stronger fault tolerance, stable performance under sudden short-circuit impact, suitable for commercial and high-demand power distribution systems.

✅ All-in-One 3-in-1 Protection One device provides earth leakage protection, overload protection and short-circuit protection. Saves space inside distribution boxes, reduces wiring points and lowers installation cost compared to separate MCB + RCD combination.

✅ Compact 1P+N Single Module Design Standard 35mm DIN rail mounting, narrow 1-module width. It maximizes available space in consumer units, perfect for compact distribution panels in residential and commercial projects.

✅ Strict International Standards & CE Approval Manufactured and tested to EN61008-1 and EN62423, CE marked. Fully accepted for EU export, overseas electrical projects and certification audit requirements.

✅ Built-in Monthly Test Button Easy regular function test. Electricians can verify the residual current protection function with one press to ensure long-term reliable safety.

✅ Robust & Stable Performance High-quality flame-retardant housing, reliable internal electromagnetic trip mechanism, long mechanical and electrical service life, low false tripping rate under normal working conditions.

Technical Specifications

ItemParameter
ModelLMB1-63B
BrandLVMA
Product TypeType B RCCB
Pole1P+N / 3P+N
Rated Current (In)63A
Rated Residual Operating Current (IΔn)30mA
Rated Voltage230/240V AC
Frequency50/60Hz
Rated Breaking Capacity10kA
Compliance StandardsEN61008-1, EN62423
CertificateCE
Mounting35mm DIN Rail

Typical Applications

  • EV charging circuits / Mode 3 EV charging points
  • Solar PV inverter & battery energy storage systems
  • Variable frequency drives (VFD), frequency converters
  • Heat pumps and inverter air-conditioning equipment
  • Modern residential distribution boards
  • Commercial buildings, workshops and automation equipment with DC leakage risk

Important Notes

  • Press the TEST button every month to confirm the residual current protection works normally.
  • Type A / AC RCBO cannot replace Type B for EV and solar circuits, as they cannot detect smooth DC leakage faults.
  • Installation must be completed by a qualified professional electrician in accordance with local wiring regulations.

FAQ Section

Q: What is the difference between Type B RCBO and Type A RCBO? A: Type B RCBO can detect AC, pulsating DC and smooth DC leakage currents. Type A only detects AC and pulsating DC. For EV chargers and solar inverters, smooth DC leakage may occur, so Type B is mandatory for reliable protection.

Q: Is this LVMA LMB1-63B suitable for EV charger installation? A: Yes, this Type B RCBO is widely used for EV charging point circuits and meets the protection requirements for DC leakage faults in charging systems.

Q: What does 10kA breaking capacity mean? A: 10kA means the RCBO can safely interrupt short-circuit current up to 10000A, offering higher reliability for commercial circuits than standard 6kA models.

Q: Can this RCBO be used for solar inverter output? A: Yes, it is a preferred protective device for the AC side of transformerless solar inverters and energy storage systems.

Data Download

LVMA low voltage selection manual

Related Products

Contact Us

Have questions about our products or services? Our team is here to help you with any inquiries.

Email Address

Your Name

Your phone

Message

Contact Information

Follow Us