LMB5L-40 C25 RCBO | 40A 30mA 6kA Earth Leakage Circuit Breaker
LMB5L-40 C25 RCBO | 40A 30mA 6kA Earth Leakage Circuit Breaker
Rated voltage(V):230
Pole:1P+N
Shell-level rated current(A):40A
Rated current(A):6,10,16,20,25,32,40
Rated breaking residual current(mA):10、30、100
Breaking capacity(A):6000
Mounting size:18*79*85
Rated voltage(V):230
Pole:1P+N
Shell-level rated current(A):40A
Rated current(A):6,10,16,20,25,32,40
Rated breaking residual current(mA):10、30、100
Breaking capacity(A):6000
Mounting size:18*79*85
1. Product Overview
2. Core Technical Specifications
| Item | Parameter |
|---|---|
| Brand | LVMA |
| Model | LMB5L-40 |
| Pole Type | 1P+N (Single Pole + Neutral) |
| Rated Current (In) | 25A |
| Rated Voltage | AC 230V, 50/60Hz |
| Residual Operating Current (IΔn) | 10,30,100 mA |
| Maximum Breaking Capacity | 6000A (6kA) |
| Leakage Trip Time | ≤0.1s ultra-fast response |
| Trip Curve | C Curve (suitable for lighting, socket, household appliance loads) |
| Mounting Standard | 35mm standard DIN rail |
| Certification | CE |
| Test Function | Built-in manual TEST button for regular performance check |
| Operating Temperature | -5℃ ~ +40℃ |
| Test current | Rated current | Requested time | Result | Start station | Remark |
|---|---|---|---|---|---|
| 1.13In | All | t≤1h | Don’t trip | Cool | |
| 1.45In | t<1h | Trip | Heat | Current ascends the requested value stably in 5s | |
| 2.55In | In≤32A | Is<t<60s | Trip | Cool | Auxiiary switch closed and power on |
| 2.55In | In≤32A | Is<t<120s | Trip | Cool | |
| 5In | All | t≤0.1s | Don’t trip | Cool | |
| 10In | t≤0.1s | Trip | Cool |
3. Key Product Advantages
- 3-in-1 Integrated Protection
Covers earth leakage anti-shock protection, overload overheating protection and short-circuit instant cut-off protection, one unit solves three major circuit safety risks.
- 0.1s Rapid Fault Tripping
30mA sensitive leakage trigger ensures power cut within 0.1 second once electric leakage happens, greatly reducing electric shock injury probability.
- 6kA High Short-Circuit Resistance
Strong breaking capacity withstands instant large short-circuit current, avoids internal burnout and explosion of the breaker under fault conditions.
- C Curve Household Matching Design
C-type trip curve tolerates small starting current of household electrical equipment like air conditioners, refrigerators and water heaters, no nuisance tripping in daily use.
- Compact DIN Rail Installation
Ultra-narrow single-module body, saves distribution box internal space, easy snap-on mounting on standard 35mm DIN rail, convenient wiring with top & bottom double screw terminals.
- Built-in Test Button
Equipped with orange T test button for monthly functional inspection to guarantee long-term stable leakage protection performance.
- Strict CE Quality Certification
Comply with international electrical safety standards, safe for export to European, Southeast Asian and global markets.
4. Application Scenarios
- Residential household power distribution boxes: wall sockets, lighting circuits, kitchen & bathroom high-leakage-risk loops
- Small retail shops, office single-phase power distribution systems
- Apartment building centralized electrical control cabinets
- Light commercial equipment single-phase power supply protection
- Renovation & new construction low-voltage electrical wiring projects
5. Operation Instructions
- Install the breaker onto standard 35mm DIN rail inside distribution box; connect live wire and neutral wire to top two terminals, load wires to bottom two terminals.
- Push the black switch handle upward to “ON” position to supply power to downstream circuits.
- Press the orange “T” TEST button monthly when power is on. If the breaker trips automatically, the leakage protection function works normally; if no trip, replace the breaker immediately.
- When leakage/overload/short-circuit fault occurs, the handle will jump to “OFF”. Cut off all electrical loads first, check circuit hidden troubles, then reset after eliminating faults.
6. Package & After-sales
- Support OEM & ODM custom logo, customized packing box service
- 2-year factory warranty, free replacement for quality defects under normal operation
7. FAQ
Q1: What does 30mA mean for this RCBO?
Q2: Difference between C curve and B curve?
Q3: Can this breaker be exported to Europe?
Q4: How often should I press the TEST button?
1. Product Overview
2. Core Technical Specifications
| Item | Parameter |
|---|---|
| Brand | LVMA |
| Model | LMB5L-40 |
| Pole Type | 1P+N (Single Pole + Neutral) |
| Rated Current (In) | 25A |
| Rated Voltage | AC 230V, 50/60Hz |
| Residual Operating Current (IΔn) | 10,30,100 mA |
| Maximum Breaking Capacity | 6000A (6kA) |
| Leakage Trip Time | ≤0.1s ultra-fast response |
| Trip Curve | C Curve (suitable for lighting, socket, household appliance loads) |
| Mounting Standard | 35mm standard DIN rail |
| Certification | CE |
| Test Function | Built-in manual TEST button for regular performance check |
| Operating Temperature | -5℃ ~ +40℃ |
| Test current | Rated current | Requested time | Result | Start station | Remark |
|---|---|---|---|---|---|
| 1.13In | All | t≤1h | Don’t trip | Cool | |
| 1.45In | t<1h | Trip | Heat | Current ascends the requested value stably in 5s | |
| 2.55In | In≤32A | Is<t<60s | Trip | Cool | Auxiiary switch closed and power on |
| 2.55In | In≤32A | Is<t<120s | Trip | Cool | |
| 5In | All | t≤0.1s | Don’t trip | Cool | |
| 10In | t≤0.1s | Trip | Cool |
3. Key Product Advantages
- 3-in-1 Integrated Protection
Covers earth leakage anti-shock protection, overload overheating protection and short-circuit instant cut-off protection, one unit solves three major circuit safety risks.
- 0.1s Rapid Fault Tripping
30mA sensitive leakage trigger ensures power cut within 0.1 second once electric leakage happens, greatly reducing electric shock injury probability.
- 6kA High Short-Circuit Resistance
Strong breaking capacity withstands instant large short-circuit current, avoids internal burnout and explosion of the breaker under fault conditions.
- C Curve Household Matching Design
C-type trip curve tolerates small starting current of household electrical equipment like air conditioners, refrigerators and water heaters, no nuisance tripping in daily use.
- Compact DIN Rail Installation
Ultra-narrow single-module body, saves distribution box internal space, easy snap-on mounting on standard 35mm DIN rail, convenient wiring with top & bottom double screw terminals.
- Built-in Test Button
Equipped with orange T test button for monthly functional inspection to guarantee long-term stable leakage protection performance.
- Strict CE Quality Certification
Comply with international electrical safety standards, safe for export to European, Southeast Asian and global markets.
4. Application Scenarios
- Residential household power distribution boxes: wall sockets, lighting circuits, kitchen & bathroom high-leakage-risk loops
- Small retail shops, office single-phase power distribution systems
- Apartment building centralized electrical control cabinets
- Light commercial equipment single-phase power supply protection
- Renovation & new construction low-voltage electrical wiring projects
5. Operation Instructions
- Install the breaker onto standard 35mm DIN rail inside distribution box; connect live wire and neutral wire to top two terminals, load wires to bottom two terminals.
- Push the black switch handle upward to “ON” position to supply power to downstream circuits.
- Press the orange “T” TEST button monthly when power is on. If the breaker trips automatically, the leakage protection function works normally; if no trip, replace the breaker immediately.
- When leakage/overload/short-circuit fault occurs, the handle will jump to “OFF”. Cut off all electrical loads first, check circuit hidden troubles, then reset after eliminating faults.
6. Package & After-sales
- Support OEM & ODM custom logo, customized packing box service
- 2-year factory warranty, free replacement for quality defects under normal operation
7. FAQ
Q1: What does 30mA mean for this RCBO?
Q2: Difference between C curve and B curve?
Q3: Can this breaker be exported to Europe?
Q4: How often should I press the TEST button?
Related Products
Contact Us
Have questions about our products or services? Our team is here to help you with any inquiries.