GV2 Series Motor Protection Circuit Breaker | GV2P / GV2ME MPCB

GV2 Series Motor Protection Circuit Breaker | GV2P / GV2ME MPCB

The GV2 series motor protection circuit breaker (MPCB) integrates motor control, overload thermal protection and instantaneous short-circuit protection in a single compact DIN rail module, available in two handle variants: rotary knob type (GV2P series) and push-button start-stop type (GV2ME series). With fully adjustable rated current dial for matching different three-phase motors, it features a dedicated TEST function for regular performance inspection, standard 3P L1/L2/L3 main circuit terminals and auxiliary signal contact ports. Widely used for CNC machine tools, water pumps, fans, compressors and all kinds of small-medium industrial three-phase asynchronous motor control & safety protection.

The GV2 series motor protection circuit breaker (MPCB) integrates motor control, overload thermal protection and instantaneous short-circuit protection in a single compact DIN rail module, available in two handle variants: rotary knob type (GV2P series) and push-button start-stop type (GV2ME series). With fully adjustable rated current dial for matching different three-phase motors, it features a dedicated TEST function for regular performance inspection, standard 3P L1/L2/L3 main circuit terminals and auxiliary signal contact ports. Widely used for CNC machine tools, water pumps, fans, compressors and all kinds of small-medium industrial three-phase asynchronous motor control & safety protection.

1. Product Overview

The GV2 motor protection circuit breaker (MPCB) is an all-in-one dedicated protection device exclusively designed for three-phase AC asynchronous motors, replacing the separate combination of circuit breaker + contactor + thermal overload relay into one modular unit.

This series provides two mainstream operation versions to meet different workshop operation habits:

  1. GV2P Series: Rotary green-black switch handle, manual ON/OFF operation with TRIP fault lockout position
  2. GV2ME Series: Independent green START push button & red STOP push button, intuitive one-click motor start and emergency stop

    All models adopt adjustable thermal-magnetic dual trip mechanism, with front current regulation dial to match motor rated current. Standard 35mm DIN rail mounting, clear L1/L2/L3 input and T1/T2/T3 load output terminals, reserved auxiliary contact interfaces for fault signal feedback, ideal for machine tool control cabinets, HVAC equipment, pumping stations and automated production line motor power control.

2. Core Product Features

1. Two Optional Operation Structures for Different Scenarios

Type 1: GV2P Rotary Knob Version

  • Integrated rotary green lever handle with 3 positions: OFF → ON → TRIP
  • Automatic lock at TRIP position after overload/short-circuit fault, must manually reset to restore power, avoid accidental motor restart during fault maintenance
  • Simple single-hand operation, compact structure saving cabinet space, suitable for unattended motor equipment

Type 2: GV2ME Push Button Start-Stop Version

  • Separate green START button for motor power-on, red emergency STOP button for instant power cut
  • Independent emergency stop button meets industrial safety operation standards, convenient for frequent manual start-stop equipment like machine tools
  • Clear visual distinction of start/stop buttons, reduce misoperation risks for workshop operators

2. Adjustable Thermal-Magnetic Dual Protection System

  1. Thermal Overload Protection: Front adjustable current dial, set trip current according to motor rated load; bimetallic strip delayed trip prevents motor winding burnout under long-time overload
  2. Instant Magnetic Short-Circuit Protection: Electromagnetic trip structure cuts power within milliseconds when short circuit occurs, block huge surge current to protect motor coils and upstream cables

    All protection thresholds can be precisely calibrated on-site without extra auxiliary components.

3. Built-in Independent TEST Inspection Function

Dedicated TEST button on front panel, users can simulate overload trip condition periodically to verify the MPCB protection function intact, no need to disassemble wiring for safety inspection.

4. Standard 3P Full Three-Phase Isolation Design

3 main poles simultaneously disconnect L1, L2, L3 three live phases when tripped or switched OFF, forming complete visible isolation gap, fully compliant with electrical maintenance safety standards to eliminate residual live hidden danger. Clear terminal marking: 1L1/3L2/5L3 power input, 2T1/4T2/6T3 motor load output, avoid reverse wiring errors.

5. Reserved Auxiliary Contact Interface

Built-in auxiliary contact terminal slots (13/14, 18 etc.), can install NO/NC auxiliary contacts to transmit fault trip signal to PLC, alarm light or buzzer, realize remote motor fault monitoring for automated production lines.

6. Compact DIN Rail Modular Installation

Single module width design, directly snap onto universal 35mm DIN rail inside all standard industrial distribution cabinets, high flame-retardant insulated plastic housing with heat dissipation grille on top, effectively release internal heat during long-time motor full-load operation.

7. Wide Matching Current Range

Full segmented adjustable current grades cover small to medium three-phase motors:

0.1A ~ 32A complete specifications, can match fans, pumps, compressors, CNC machine tool spindles and other low & medium power industrial motors.

3. Working Conditions

This GV2 motor protection circuit breaker maintains stable motor control & protection performance under standard industrial indoor environments:
  1. Rated Operational Voltage: AC 400V 50Hz three-phase
  2. Ambient operating temperature: -10℃ ~ +55℃
  3. Protection Grade: IP20, only installed inside fully enclosed indoor control cabinets; not suitable for outdoor splash, heavy dust or salt fog environments
  4. Surrounding atmosphere: Free of corrosive gas, flammable dust and conductive metal particles
  5. Altitude: Full rated protection performance below 2000 meters above sea level
  6. Vibration resistance: Tolerate mild mechanical vibration of machine tool workshops; avoid continuous strong impact
  7. Humidity: Relative humidity ≤85%, no condensation inside the MPCB housing

4. Unified Technical Specifications

ParameterUnified Specification for GV2 Series MPCB
Product SeriesGV2P (Rotary Handle) / GV2ME (Push Button Start-Stop) Motor Protection Circuit Breaker
Poles3P Three Phase (L1 L2 L3 input, T1 T2 T3 motor output)
Rated Working VoltageAC 400V 50Hz
Protection MechanismThermal overload delayed trip + magnetic instantaneous short-circuit trip
Adjustable Current RangeFull grades 0.1A ~ 32A customizable
Operation ModeGV2P: Rotary ON/OFF/TRIP lever; GV2ME: Separate START / STOP push buttons
Inspection FunctionFront manual TEST button for protection function verification
Auxiliary FunctionReserved auxiliary contact mounting port for fault signal feedback
Mounting MethodStandard 35mm DIN rail modular snap-in installation
Housing MaterialHigh flame-retardant heat-dissipating insulated engineering plastic
Core FunctionsThree-phase motor manual control, overload protection, short-circuit fault protection

5. Typical Applications

  • CNC lathe, milling machine, textile machinery spindle motor control cabinets
  • Industrial water pumps, sewage pumps, cooling fan motor safety protection
  • HVAC central air conditioning, air compressor, refrigeration equipment motor control
  • Automated assembly line, packaging machine, conveyor belt motor power control
  • Agricultural irrigation pump, ventilation fan three-phase motor distribution box
  • Small industrial production equipment independent motor safety switch

6. Frequently Asked Questions (FAQ)

1. What is the difference between GV2P and GV2ME models?

GV2P adopts integrated rotary handle, suitable for motors that rarely start and stop automatically, with fault trip lockout function; GV2ME uses separate green START and red emergency STOP buttons, convenient for equipment requiring frequent manual operation and emergency power cut, widely used on machine tools. Their internal protection performance, current range and wiring terminals are completely consistent.

2. Why choose MPCB instead of ordinary MCB miniature circuit breaker for motors?

Ordinary MCB only has short-circuit protection without delayed overload protection, cannot protect motor winding from burnout under long-time overload. GV2 MPCB has adjustable thermal overload trip curve specially optimized for motor starting surge current, will not falsely trip during normal motor startup while cutting power timely under sustained overload.

3. Can I install auxiliary contacts on this GV2 breaker?

Yes, the side of the device reserves standard auxiliary contact mounting slots, you can match NO/NC auxiliary contacts to output fault trip signals to PLC or external alarm devices for remote monitoring.

4. How to set the correct protection current dial for a motor?

Adjust the front current dial value equal to the rated current marked on the motor nameplate, to ensure overload protection takes effect when motor runs over rated load.

5. Can the TEST button be pressed frequently?

Yes, the TEST button is designed for regular monthly inspection, simulating overload trip state to confirm the protection function is normal. If the breaker does not trip after pressing the TEST button, the product needs to be replaced immediately.

6. Is outdoor installation allowed?

Not recommended, IP20 protection grade only supports installation inside sealed indoor control cabinets. Outdoor rain, moisture and dust will corrode internal bimetallic strip and magnetic components, leading to protection failure.

7. Technical Documentation & Support

Download the full datasheet for detailed specifications, wiring diagrams, and installation instructions.
Exclusive project customization supports OEM/ODM mode, contact our technical team to create a complete set of landing solutions for you.
Request a quote with your project details for bulk pricing, lead times, and compliance certifications.

1. Product Overview

The GV2 motor protection circuit breaker (MPCB) is an all-in-one dedicated protection device exclusively designed for three-phase AC asynchronous motors, replacing the separate combination of circuit breaker + contactor + thermal overload relay into one modular unit.

This series provides two mainstream operation versions to meet different workshop operation habits:

  1. GV2P Series: Rotary green-black switch handle, manual ON/OFF operation with TRIP fault lockout position
  2. GV2ME Series: Independent green START push button & red STOP push button, intuitive one-click motor start and emergency stop

    All models adopt adjustable thermal-magnetic dual trip mechanism, with front current regulation dial to match motor rated current. Standard 35mm DIN rail mounting, clear L1/L2/L3 input and T1/T2/T3 load output terminals, reserved auxiliary contact interfaces for fault signal feedback, ideal for machine tool control cabinets, HVAC equipment, pumping stations and automated production line motor power control.

2. Core Product Features

1. Two Optional Operation Structures for Different Scenarios

Type 1: GV2P Rotary Knob Version

  • Integrated rotary green lever handle with 3 positions: OFF → ON → TRIP
  • Automatic lock at TRIP position after overload/short-circuit fault, must manually reset to restore power, avoid accidental motor restart during fault maintenance
  • Simple single-hand operation, compact structure saving cabinet space, suitable for unattended motor equipment

Type 2: GV2ME Push Button Start-Stop Version

  • Separate green START button for motor power-on, red emergency STOP button for instant power cut
  • Independent emergency stop button meets industrial safety operation standards, convenient for frequent manual start-stop equipment like machine tools
  • Clear visual distinction of start/stop buttons, reduce misoperation risks for workshop operators

2. Adjustable Thermal-Magnetic Dual Protection System

  1. Thermal Overload Protection: Front adjustable current dial, set trip current according to motor rated load; bimetallic strip delayed trip prevents motor winding burnout under long-time overload
  2. Instant Magnetic Short-Circuit Protection: Electromagnetic trip structure cuts power within milliseconds when short circuit occurs, block huge surge current to protect motor coils and upstream cables

    All protection thresholds can be precisely calibrated on-site without extra auxiliary components.

3. Built-in Independent TEST Inspection Function

Dedicated TEST button on front panel, users can simulate overload trip condition periodically to verify the MPCB protection function intact, no need to disassemble wiring for safety inspection.

4. Standard 3P Full Three-Phase Isolation Design

3 main poles simultaneously disconnect L1, L2, L3 three live phases when tripped or switched OFF, forming complete visible isolation gap, fully compliant with electrical maintenance safety standards to eliminate residual live hidden danger. Clear terminal marking: 1L1/3L2/5L3 power input, 2T1/4T2/6T3 motor load output, avoid reverse wiring errors.

5. Reserved Auxiliary Contact Interface

Built-in auxiliary contact terminal slots (13/14, 18 etc.), can install NO/NC auxiliary contacts to transmit fault trip signal to PLC, alarm light or buzzer, realize remote motor fault monitoring for automated production lines.

6. Compact DIN Rail Modular Installation

Single module width design, directly snap onto universal 35mm DIN rail inside all standard industrial distribution cabinets, high flame-retardant insulated plastic housing with heat dissipation grille on top, effectively release internal heat during long-time motor full-load operation.

7. Wide Matching Current Range

Full segmented adjustable current grades cover small to medium three-phase motors:

0.1A ~ 32A complete specifications, can match fans, pumps, compressors, CNC machine tool spindles and other low & medium power industrial motors.

3. Working Conditions

This GV2 motor protection circuit breaker maintains stable motor control & protection performance under standard industrial indoor environments:
  1. Rated Operational Voltage: AC 400V 50Hz three-phase
  2. Ambient operating temperature: -10℃ ~ +55℃
  3. Protection Grade: IP20, only installed inside fully enclosed indoor control cabinets; not suitable for outdoor splash, heavy dust or salt fog environments
  4. Surrounding atmosphere: Free of corrosive gas, flammable dust and conductive metal particles
  5. Altitude: Full rated protection performance below 2000 meters above sea level
  6. Vibration resistance: Tolerate mild mechanical vibration of machine tool workshops; avoid continuous strong impact
  7. Humidity: Relative humidity ≤85%, no condensation inside the MPCB housing

4. Unified Technical Specifications

ParameterUnified Specification for GV2 Series MPCB
Product SeriesGV2P (Rotary Handle) / GV2ME (Push Button Start-Stop) Motor Protection Circuit Breaker
Poles3P Three Phase (L1 L2 L3 input, T1 T2 T3 motor output)
Rated Working VoltageAC 400V 50Hz
Protection MechanismThermal overload delayed trip + magnetic instantaneous short-circuit trip
Adjustable Current RangeFull grades 0.1A ~ 32A customizable
Operation ModeGV2P: Rotary ON/OFF/TRIP lever; GV2ME: Separate START / STOP push buttons
Inspection FunctionFront manual TEST button for protection function verification
Auxiliary FunctionReserved auxiliary contact mounting port for fault signal feedback
Mounting MethodStandard 35mm DIN rail modular snap-in installation
Housing MaterialHigh flame-retardant heat-dissipating insulated engineering plastic
Core FunctionsThree-phase motor manual control, overload protection, short-circuit fault protection

5. Typical Applications

  • CNC lathe, milling machine, textile machinery spindle motor control cabinets
  • Industrial water pumps, sewage pumps, cooling fan motor safety protection
  • HVAC central air conditioning, air compressor, refrigeration equipment motor control
  • Automated assembly line, packaging machine, conveyor belt motor power control
  • Agricultural irrigation pump, ventilation fan three-phase motor distribution box
  • Small industrial production equipment independent motor safety switch

6. Frequently Asked Questions (FAQ)

1. What is the difference between GV2P and GV2ME models?

GV2P adopts integrated rotary handle, suitable for motors that rarely start and stop automatically, with fault trip lockout function; GV2ME uses separate green START and red emergency STOP buttons, convenient for equipment requiring frequent manual operation and emergency power cut, widely used on machine tools. Their internal protection performance, current range and wiring terminals are completely consistent.

2. Why choose MPCB instead of ordinary MCB miniature circuit breaker for motors?

Ordinary MCB only has short-circuit protection without delayed overload protection, cannot protect motor winding from burnout under long-time overload. GV2 MPCB has adjustable thermal overload trip curve specially optimized for motor starting surge current, will not falsely trip during normal motor startup while cutting power timely under sustained overload.

3. Can I install auxiliary contacts on this GV2 breaker?

Yes, the side of the device reserves standard auxiliary contact mounting slots, you can match NO/NC auxiliary contacts to output fault trip signals to PLC or external alarm devices for remote monitoring.

4. How to set the correct protection current dial for a motor?

Adjust the front current dial value equal to the rated current marked on the motor nameplate, to ensure overload protection takes effect when motor runs over rated load.

5. Can the TEST button be pressed frequently?

Yes, the TEST button is designed for regular monthly inspection, simulating overload trip state to confirm the protection function is normal. If the breaker does not trip after pressing the TEST button, the product needs to be replaced immediately.

6. Is outdoor installation allowed?

Not recommended, IP20 protection grade only supports installation inside sealed indoor control cabinets. Outdoor rain, moisture and dust will corrode internal bimetallic strip and magnetic components, leading to protection failure.

7. Technical Documentation & Support

Download the full datasheet for detailed specifications, wiring diagrams, and installation instructions.
Exclusive project customization supports OEM/ODM mode, contact our technical team to create a complete set of landing solutions for you.
Request a quote with your project details for bulk pricing, lead times, and compliance certifications.

Data Download

LVMA low voltage selection manual

Related Products

Contact Us

Have questions about our products or services? Our team is here to help you with any inquiries.

Email Address

Your Name

Your phone

Message

Contact Information

Follow Us