LMS1-L Series ATS Solenoid-type

LMS1-L Series ATS Solenoid-type

Model Name: LMS1-L
Rated Voltage: AC230A,AC400V
Rated Current: 63A,125A,250A,630A
Pole: 2P,3P,4P
Product Category: PC Class
Features: 2 Position
Drive Mode: Solenoid-type
Certification: CE, CB, CCC
Standard: IEC 60947-6-1

Model Name: LMS1-L
Rated Voltage: AC230A,AC400V
Rated Current: 63A,125A,250A,630A
Pole: 2P,3P,4P
Product Category: PC Class
Features: 2 Position
Drive Mode: Solenoid-type
Certification: CE, CB, CCC
Standard: IEC 60947-6-1

Product details

LMS1-L can detect the status of two power supply (main power supply and standby power supply) , and automatically switch to the standby power supply in the case of main power failure, too low voltage, too high voltage, abnormal frequency, etc. , to ensure the continuity of the power load, switching time of 30 milliseconds to ensure that electrical equipment will not stop working due to power outages. When the main power supply return to normal, can automatically switch back to the main power supply.

Model Description

​

Main Technical Parameters

ModelLMS1-L
Insulation voltageAC 690V
Rated voltageAC 400V
Rated current20A~125A160A~250A315A~630A
Rated impulse withstand voltage8kV
Kind of throwDouble throw
Wiring methodFront board
Short-time resistance current10kA
Through to breaking capacity17kA
Transfer timeA PowerInput80ms80ms100ms
Break30ms30ms30ms
B PowerInput100ms100ms120ms
Break30ms30ms30ms
Electrical Life10001000
Mechanical Life50004000
Use typeAC-33ib
AccessariesManual handle

Structure and Mounting Dimensions

 

Product details

LMS1-L can detect the status of two power supply (main power supply and standby power supply) , and automatically switch to the standby power supply in the case of main power failure, too low voltage, too high voltage, abnormal frequency, etc. , to ensure the continuity of the power load, switching time of 30 milliseconds to ensure that electrical equipment will not stop working due to power outages. When the main power supply return to normal, can automatically switch back to the main power supply.

Model Description

​

Main Technical Parameters

ModelLMS1-L
Insulation voltageAC 690V
Rated voltageAC 400V
Rated current20A~125A160A~250A315A~630A
Rated impulse withstand voltage8kV
Kind of throwDouble throw
Wiring methodFront board
Short-time resistance current10kA
Through to breaking capacity17kA
Transfer timeA PowerInput80ms80ms100ms
Break30ms30ms30ms
B PowerInput100ms100ms120ms
Break30ms30ms30ms
Electrical Life10001000
Mechanical Life50004000
Use typeAC-33ib
AccessariesManual handle