GV2 0.1~80A(adjustable) Motor Protection Circuit Breaker MPCB
GV2 0.1~80A(adjustable) Motor Protection Circuit Breaker MPCB
The LVMA GV2 is a 3-pole motor protection circuit breaker (MPCB) combining adjustable overload, short-circuit protection, and manual START/STOP control for three-phase AC motors. DIN rail mount, AC-3 rated, ideal for pumps, fans, and industrial machinery.
The LVMA GV2 is a 3-pole motor protection circuit breaker (MPCB) combining adjustable overload, short-circuit protection, and manual START/STOP control for three-phase AC motors. DIN rail mount, AC-3 rated, ideal for pumps, fans, and industrial machinery.
1. Product Overview
2. Key Specifications
| Parameter | Details |
|---|---|
| Model | GV2 |
| Rated Current Range | 0.1-80A (adjustable) |
| Poles | 3P |
| Rated Operational Voltage (Ue) | AC 690V / 50/60Hz |
| Rated Insulation Voltage (Ui) | AC 690V |
| Rated Impulse Withstand Voltage (Uimp) | 6kV |
| Short-Circuit Breaking Capacity | 100kA (at 400V) |
| Utilization Category | AC-3 (motor starting/stopping) |
| Protection Functions | Overload protection, Short-circuit protection, Manual isolation |
| Reset Mode | Manual (red STOP / black START buttons) |
| Mounting Type | 35mm DIN rail mount |
| Compliance Standards | IEC 60947-2, IEC 60947-4-1 |
| Operating Temperature | -20°C ~ +60°C |
| Mechanical Life | ≥100,000 operations |
| Electrical Life (AC-3) | ≥100,000 operations at rated load |

3. Core Features
✅ Adjustable Overload Protection: Rotary dial for precise setting of motor full-load current (0.1-80A) to match specific motor ratings.
✅ Integrated Short-Circuit Protection: Fast-acting magnetic trip element provides instant protection against short-circuit faults.
✅ Combined Control & Protection: Replaces separate contactors and thermal relays, reducing component count and wiring complexity.
✅ Manual START/STOP Operation: Color-coded buttons (black START / red STOP) for safe local motor control and emergency shutdown.
✅ Isolation Function: The OFF position provides visible electrical isolation for maintenance safety.
✅ High Breaking Capacity: 100kA short-circuit withstand at 400V ensures system stability during severe faults.
✅ DIN Rail Mount Design: Compact form factor fits standard 35mm DIN rails, ideal for motor control centers and distribution panels.
✅ Test Function: Built-in TEST button allows periodic verification of overload protection functionality.
4. Applications
- Direct-on-line (DOL) motor starting for pumps, fans, and compressors
- Industrial machinery and conveyor systems
- HVAC equipment and ventilation systems
- Motor control panels and machine tools
- Small to medium-sized three-phase AC motors (0.75–30kW range)
- Agricultural and industrial equipment motor circuits
5. Why Choose LVMA GV2 MPCB?
- All-in-One Solution: Combines motor control, overload, and short-circuit protection in a single compact device, saving panel space and installation time.
- Precise Protection: Adjustable current setting ensures optimal protection tailored to the motor’s specific rating.
- Reliable Performance: Compliant with IEC 60947 standards, with high short-circuit breaking capacity and long mechanical/electrical life.
- User-Friendly Operation: Clear START/STOP buttons and visible trip status simplify troubleshooting and maintenance.
- Cost-Effective: Eliminates the need for additional contactors and relays, reducing overall system cost and complexity.
- Global Compatibility: Designed for use in 50/60Hz AC systems, suitable for industrial applications worldwide.
6. Technical Documents & Support
- Download the full datasheet for detailed specifications, wiring diagrams, and motor compatibility charts.
- Contact our engineering team for custom configurations or OEM solutions for large-scale projects.
- Request a quote with your project details for bulk pricing, lead times, and compliance certifications.
1. Product Overview
2. Key Specifications
| Parameter | Details |
|---|---|
| Model | GV2 |
| Rated Current Range | 0.1-80A (adjustable) |
| Poles | 3P |
| Rated Operational Voltage (Ue) | AC 690V / 50/60Hz |
| Rated Insulation Voltage (Ui) | AC 690V |
| Rated Impulse Withstand Voltage (Uimp) | 6kV |
| Short-Circuit Breaking Capacity | 100kA (at 400V) |
| Utilization Category | AC-3 (motor starting/stopping) |
| Protection Functions | Overload protection, Short-circuit protection, Manual isolation |
| Reset Mode | Manual (red STOP / black START buttons) |
| Mounting Type | 35mm DIN rail mount |
| Compliance Standards | IEC 60947-2, IEC 60947-4-1 |
| Operating Temperature | -20°C ~ +60°C |
| Mechanical Life | ≥100,000 operations |
| Electrical Life (AC-3) | ≥100,000 operations at rated load |

3. Core Features
✅ Adjustable Overload Protection: Rotary dial for precise setting of motor full-load current (0.1-80A) to match specific motor ratings.
✅ Integrated Short-Circuit Protection: Fast-acting magnetic trip element provides instant protection against short-circuit faults.
✅ Combined Control & Protection: Replaces separate contactors and thermal relays, reducing component count and wiring complexity.
✅ Manual START/STOP Operation: Color-coded buttons (black START / red STOP) for safe local motor control and emergency shutdown.
✅ Isolation Function: The OFF position provides visible electrical isolation for maintenance safety.
✅ High Breaking Capacity: 100kA short-circuit withstand at 400V ensures system stability during severe faults.
✅ DIN Rail Mount Design: Compact form factor fits standard 35mm DIN rails, ideal for motor control centers and distribution panels.
✅ Test Function: Built-in TEST button allows periodic verification of overload protection functionality.
4. Applications
- Direct-on-line (DOL) motor starting for pumps, fans, and compressors
- Industrial machinery and conveyor systems
- HVAC equipment and ventilation systems
- Motor control panels and machine tools
- Small to medium-sized three-phase AC motors (0.75–30kW range)
- Agricultural and industrial equipment motor circuits
5. Why Choose LVMA GV2 MPCB?
- All-in-One Solution: Combines motor control, overload, and short-circuit protection in a single compact device, saving panel space and installation time.
- Precise Protection: Adjustable current setting ensures optimal protection tailored to the motor’s specific rating.
- Reliable Performance: Compliant with IEC 60947 standards, with high short-circuit breaking capacity and long mechanical/electrical life.
- User-Friendly Operation: Clear START/STOP buttons and visible trip status simplify troubleshooting and maintenance.
- Cost-Effective: Eliminates the need for additional contactors and relays, reducing overall system cost and complexity.
- Global Compatibility: Designed for use in 50/60Hz AC systems, suitable for industrial applications worldwide.
6. Technical Documents & Support
- Download the full datasheet for detailed specifications, wiring diagrams, and motor compatibility charts.
- Contact our engineering team for custom configurations or OEM solutions for large-scale projects.
- Request a quote with your project details for bulk pricing, lead times, and compliance certifications.
Related Products
Contact Us
Have questions about our products or services? Our team is here to help you with any inquiries.