The LMGQF-100ATS is a 100A four-way single-phase intelligent automatic transfer switch (ATS) designed for 4 independent power circuits. Equipped with multi-digit digital display to real-time monitor input/output voltage and load current, it supports automatic switching between mains power and backup generator power. Built-in overvoltage, undervoltage, overload and fault alarm functions, it cuts both live and neutral lines for full isolation, standard DIN rail mounting, widely used in villas, rental apartments, commercial buildings and small solar off-grid systems for multi-circuit dual power automatic switching.

The LMGQF-100ATS is a 100A four-way single-phase intelligent automatic transfer switch (ATS) designed for 4 independent power circuits. Equipped with multi-digit digital display to real-time monitor input/output voltage and load current, it supports automatic switching between mains power and backup generator power. Built-in overvoltage, undervoltage, overload and fault alarm functions, it cuts both live and neutral lines for full isolation, standard DIN rail mounting, widely used in villas, rental apartments, commercial buildings and small solar off-grid systems for multi-circuit dual power automatic switching.

1. Product Overview

The LMGQF-100ATS 4-way automatic transfer switch is a new-generation multi-circuit dual power intelligent switching device with a rated current of 100A, independently controlling four separate single-phase power loops at the same time. It can automatically switch the load between municipal mains power and backup generator/solar power source without manual operation.

Equipped with a full digital LED display screen, users can view real-time voltage of 4 groups of input power, output voltage and load current at a glance. Integrated multiple safety protection and buzzer fault alarm, it cuts both Live (L) and Neutral (N) lines to realize complete circuit isolation. Modular DIN rail structure simplifies cabinet layout, ideal for multi-room rental housing, villa distribution systems, small commercial shops, solar off-grid power stations and equipment backup power distribution control.

2. Core Product Features

1. Independent 4 Separate Power Circuits

Four fully isolated independent L/N input channels (L1/N1, L2/N2, L3/N3, L4/N4), each group supports independent dual power automatic switching. Each circuit is equipped with an independent manual on/off small switch for single-loop maintenance without cutting off the whole device, flexible for multi-area power distribution management.

2. Real-Time Multi-Parameter Digital Display

Large digital screen simultaneously displays all core electrical data:
  • Four groups of input power supply voltage
  • Total output load current
  • Working temperature & running time
  • Real-time fault code prompt when abnormal

    Intuitive visual monitoring, no extra external voltmeter/ammeter required.

3. Auto Switch Between Mains & Backup Power

Automatic transfer logic:
  • When mains power fails / voltage out of range, automatically switch to backup generator/solar power within preset delay time
  • Automatically switch back to mains power and disconnect backup supply once mains recovers stable voltage

    Adjustable switching delay time via front navigation buttons to avoid frequent power bounce.

4. All-Round Electrical Safety Protection

image-1

Built-in multi-layer intelligent protection for all 4 channels:
  1. Overvoltage / Undervoltage protection (custom threshold adjustable)
  2. Overload overcurrent protection with automatic load cut-off
  3. Phase loss & power loss detection
  4. Over-temperature protection for internal components
  5. Complete isolation by cutting both L and N lines, no residual live wire hidden danger

5. Built-in Buzzer Fault Alarm & Signal Output

  • Onboard loud buzzer: automatically sound alarm when power supply fault, overload or over-temperature occurs, mute button available to stop alarm sound
  • NC/NO COM auxiliary signal output terminals, can connect external alarm light, PLC or remote monitoring host to upload fault signal

6. Easy Parameter Setting & Manual Operation

Central M navigation key + four-direction arrow buttons for quick adjustment of switching delay, voltage threshold, alarm mode and other parameters. Four independent red manual switches on the front, support single circuit forced on/off for maintenance and debugging work.

7. Standard DIN Rail Modular Installation

Integrated multi-module width structure, directly snap onto standard 35mm DIN rail inside distribution cabinet, matching most domestic and European standard low-voltage power boxes. Flame-retardant insulated housing with strong anti-interference internal circuit, stable operation in complex electromagnetic environments.

3. Working Conditions

This 4-way ATS maintains stable intelligent switching performance under standard indoor environments:
  1. Ambient operating temperature: -10℃ ~ +55℃
  2. Protection Grade: IP20, only installed inside enclosed indoor distribution cabinets; not suitable for outdoor splash, high humidity and heavy salt fog environments
  3. Surrounding atmosphere: Free of corrosive gas, flammable dust and conductive metal particles
  4. Altitude: Normal rated performance below 2000 meters above sea level
  5. Vibration resistance: Withstand mild mechanical vibration of indoor power rooms; avoid continuous strong impact
  6. Humidity: Relative humidity ≤85%, no condensation inside the ATS housing

4. Unified Technical Specifications

ParameterUnified Specification for LMGQF-100ATS
ModelLMGQF-100ATS-1Z 4 Way Automatic Transfer Switch
Rated Current100A
Controlled Circuits4 independent single-phase L/N channels
Rated Operating VoltageAC 230V 50Hz Single Phase
Switching ModeAuto transfer between mains & backup generator/solar power
Display FunctionDigital display of 4-channel input voltage, output current, temperature, fault code
Protection FunctionsOvervoltage, undervoltage, overload, over-temperature, power loss protection
Safety DesignCut both Live L & Neutral N lines for full isolation
Alarm SystemBuilt-in buzzer + NC/NO auxiliary fault signal output
Adjustment FunctionCustom switching delay, adjustable voltage protection thresholds
Manual ControlIndependent ON/OFF switch for each of the 4 circuits
Mounting MethodStandard 35mm DIN rail modular installation
Housing MaterialHigh flame-retardant insulating engineering plastic
Auxiliary TerminalCOM / NO / NC fault signal relay output

image-3

5. Typical Applications

  • Multi-unit rental apartment four-circuit dual power centralized control cabinet
  • Villa multi-room independent power supply automatic switching system
  • Small commercial shops, office multi-area mains-generator backup power distribution
  • Household solar off-grid / grid-tied multi-circuit power management
  • Small industrial equipment, water pump group backup power automatic switching
  • Community public lighting, elevator auxiliary dual power control panels

6. Frequently Asked Questions (FAQ)

1. What does “4 Way” mean for this ATS?

It controls 4 completely independent single-phase power circuits separately. Each loop can automatically switch between mains and backup power, and each has its own manual switch for individual maintenance without powering down other circuits.

2. Can this ATS work with solar power as backup supply?

Yes, it supports any AC backup power source including diesel generators, solar inverter output power and standby UPS power supply, with adjustable voltage detection thresholds to match different backup power equipment.

3. What is the function of cutting both L and N lines?

Most ordinary ATS only cut the live line L, while neutral line N remains connected with residual electricity risk. This model disconnects both L and N simultaneously when switching off, meeting full electrical isolation safety standards for maintenance work.

4. What is the auxiliary COM/NO/NC terminal used for?

It is a fault signal relay output port. When overvoltage, power loss or overload fault occurs, the contact state will switch, which can be connected to external alarm lights, buzzers or PLC to realize remote fault monitoring.

5. Can I adjust the automatic switching delay time?

Yes, users can set the delay seconds via the front operation buttons to prevent frequent power switching caused by instantaneous mains voltage fluctuation, protecting electrical loads from repeated power impact.

6. Is outdoor installation allowed?

Not recommended. IP20 protection grade only supports indoor cabinet installation. Outdoor rain, moisture and dust will damage the digital display and internal control circuit, leading to failure of automatic switching function.

7. Technical documentation and support

Download full datasheets including complete specs, wiring schematics and selection guides.
Reach out to our technical team for project-specific customization and OEM/ODM service.
Submit a project inquiry to receive bulk pricing, production lead times and relevant compliance certificates.

1. Product Overview

The LMGQF-100ATS 4-way automatic transfer switch is a new-generation multi-circuit dual power intelligent switching device with a rated current of 100A, independently controlling four separate single-phase power loops at the same time. It can automatically switch the load between municipal mains power and backup generator/solar power source without manual operation.

Equipped with a full digital LED display screen, users can view real-time voltage of 4 groups of input power, output voltage and load current at a glance. Integrated multiple safety protection and buzzer fault alarm, it cuts both Live (L) and Neutral (N) lines to realize complete circuit isolation. Modular DIN rail structure simplifies cabinet layout, ideal for multi-room rental housing, villa distribution systems, small commercial shops, solar off-grid power stations and equipment backup power distribution control.

2. Core Product Features

1. Independent 4 Separate Power Circuits

Four fully isolated independent L/N input channels (L1/N1, L2/N2, L3/N3, L4/N4), each group supports independent dual power automatic switching. Each circuit is equipped with an independent manual on/off small switch for single-loop maintenance without cutting off the whole device, flexible for multi-area power distribution management.

2. Real-Time Multi-Parameter Digital Display

Large digital screen simultaneously displays all core electrical data:
  • Four groups of input power supply voltage
  • Total output load current
  • Working temperature & running time
  • Real-time fault code prompt when abnormal

    Intuitive visual monitoring, no extra external voltmeter/ammeter required.

3. Auto Switch Between Mains & Backup Power

Automatic transfer logic:
  • When mains power fails / voltage out of range, automatically switch to backup generator/solar power within preset delay time
  • Automatically switch back to mains power and disconnect backup supply once mains recovers stable voltage

    Adjustable switching delay time via front navigation buttons to avoid frequent power bounce.

4. All-Round Electrical Safety Protection

image-1

Built-in multi-layer intelligent protection for all 4 channels:
  1. Overvoltage / Undervoltage protection (custom threshold adjustable)
  2. Overload overcurrent protection with automatic load cut-off
  3. Phase loss & power loss detection
  4. Over-temperature protection for internal components
  5. Complete isolation by cutting both L and N lines, no residual live wire hidden danger

5. Built-in Buzzer Fault Alarm & Signal Output

  • Onboard loud buzzer: automatically sound alarm when power supply fault, overload or over-temperature occurs, mute button available to stop alarm sound
  • NC/NO COM auxiliary signal output terminals, can connect external alarm light, PLC or remote monitoring host to upload fault signal

6. Easy Parameter Setting & Manual Operation

Central M navigation key + four-direction arrow buttons for quick adjustment of switching delay, voltage threshold, alarm mode and other parameters. Four independent red manual switches on the front, support single circuit forced on/off for maintenance and debugging work.

7. Standard DIN Rail Modular Installation

Integrated multi-module width structure, directly snap onto standard 35mm DIN rail inside distribution cabinet, matching most domestic and European standard low-voltage power boxes. Flame-retardant insulated housing with strong anti-interference internal circuit, stable operation in complex electromagnetic environments.

3. Working Conditions

This 4-way ATS maintains stable intelligent switching performance under standard indoor environments:
  1. Ambient operating temperature: -10℃ ~ +55℃
  2. Protection Grade: IP20, only installed inside enclosed indoor distribution cabinets; not suitable for outdoor splash, high humidity and heavy salt fog environments
  3. Surrounding atmosphere: Free of corrosive gas, flammable dust and conductive metal particles
  4. Altitude: Normal rated performance below 2000 meters above sea level
  5. Vibration resistance: Withstand mild mechanical vibration of indoor power rooms; avoid continuous strong impact
  6. Humidity: Relative humidity ≤85%, no condensation inside the ATS housing

4. Unified Technical Specifications

ParameterUnified Specification for LMGQF-100ATS
ModelLMGQF-100ATS-1Z 4 Way Automatic Transfer Switch
Rated Current100A
Controlled Circuits4 independent single-phase L/N channels
Rated Operating VoltageAC 230V 50Hz Single Phase
Switching ModeAuto transfer between mains & backup generator/solar power
Display FunctionDigital display of 4-channel input voltage, output current, temperature, fault code
Protection FunctionsOvervoltage, undervoltage, overload, over-temperature, power loss protection
Safety DesignCut both Live L & Neutral N lines for full isolation
Alarm SystemBuilt-in buzzer + NC/NO auxiliary fault signal output
Adjustment FunctionCustom switching delay, adjustable voltage protection thresholds
Manual ControlIndependent ON/OFF switch for each of the 4 circuits
Mounting MethodStandard 35mm DIN rail modular installation
Housing MaterialHigh flame-retardant insulating engineering plastic
Auxiliary TerminalCOM / NO / NC fault signal relay output

image-3

5. Typical Applications

  • Multi-unit rental apartment four-circuit dual power centralized control cabinet
  • Villa multi-room independent power supply automatic switching system
  • Small commercial shops, office multi-area mains-generator backup power distribution
  • Household solar off-grid / grid-tied multi-circuit power management
  • Small industrial equipment, water pump group backup power automatic switching
  • Community public lighting, elevator auxiliary dual power control panels

6. Frequently Asked Questions (FAQ)

1. What does “4 Way” mean for this ATS?

It controls 4 completely independent single-phase power circuits separately. Each loop can automatically switch between mains and backup power, and each has its own manual switch for individual maintenance without powering down other circuits.

2. Can this ATS work with solar power as backup supply?

Yes, it supports any AC backup power source including diesel generators, solar inverter output power and standby UPS power supply, with adjustable voltage detection thresholds to match different backup power equipment.

3. What is the function of cutting both L and N lines?

Most ordinary ATS only cut the live line L, while neutral line N remains connected with residual electricity risk. This model disconnects both L and N simultaneously when switching off, meeting full electrical isolation safety standards for maintenance work.

4. What is the auxiliary COM/NO/NC terminal used for?

It is a fault signal relay output port. When overvoltage, power loss or overload fault occurs, the contact state will switch, which can be connected to external alarm lights, buzzers or PLC to realize remote fault monitoring.

5. Can I adjust the automatic switching delay time?

Yes, users can set the delay seconds via the front operation buttons to prevent frequent power switching caused by instantaneous mains voltage fluctuation, protecting electrical loads from repeated power impact.

6. Is outdoor installation allowed?

Not recommended. IP20 protection grade only supports indoor cabinet installation. Outdoor rain, moisture and dust will damage the digital display and internal control circuit, leading to failure of automatic switching function.

7. Technical documentation and support

Download full datasheets including complete specs, wiring schematics and selection guides.
Reach out to our technical team for project-specific customization and OEM/ODM service.
Submit a project inquiry to receive bulk pricing, production lead times and relevant compliance certificates.

Data Download

LVMA low voltage selection manual

Related Products

Contact Us

Have questions about our products or services? Our team is here to help you with any inquiries.

Email Address

Your Name

Your phone

Message

Contact Information

Follow Us