6L2 Pointer Type Ammeter | Industrial 30A-2000A AC Panel Meter

6L2 Pointer Type Ammeter | Industrial 30A-2000A AC Panel Meter

The 6L2 series is a classic analog pointer-type AC ammeter available in current ranges from 30A to 2000A. Featuring class 1.5 accuracy and standard 80×80mm panel mounting, it provides stable real-time current monitoring for low-voltage distribution cabinets, switchgears and industrial control panels, compatible with matching current transformers for high-current applications.

The 6L2 series is a classic analog pointer-type AC ammeter available in current ranges from 30A to 2000A. Featuring class 1.5 accuracy and standard 80×80mm panel mounting, it provides stable real-time current monitoring for low-voltage distribution cabinets, switchgears and industrial control panels, compatible with matching current transformers for high-current applications.

Product Overview

The 6L2 series analog AC ammeter is a widely adopted panel-mounted measuring instrument dedicated to real-time alternating current monitoring in low-voltage power systems. Covering a comprehensive current range from 30A direct connection up to 2000A (2KA) via matched current transformers, it adapts to branch circuit monitoring as well as high-current main feeder measurement.
Built around a precision moving-coil movement with magnetic damping technology, the 6L2 ammeter delivers smooth, jitter-free pointer deflection and fast response to load fluctuations. Its universal 80×80mm front panel dimension and standard 76×76mm mounting cutout are compatible with the vast majority of electrical enclosures on the market, supporting both new installation projects and drop-in retrofit replacement of existing panel meters.
Trusted by switchgear manufacturers, electrical panel builders, system integrators and MEP contractors, the 6L2 ammeter series offers proven field reliability, cost efficiency and flexible specification options, making it a staple component in industrial, commercial and infrastructure power distribution systems.

Core Features & Advantages

  • Ultra-wide current coverage: Full range from 30A to 2000A, with direct-connection models for low currents and CT-operated models for high-current circuits.
  • High-contrast clear dial: Matte white background with bold black scale markings and major graduations, enabling fast, error-free reading even from standard operating distances.
  • Class 1.5 measurement accuracy: Calibrated precision movement with a stable permanent magnetic circuit, compliant with mainstream industrial electrical metering standards.
  • Magnetic damping structure: Effectively suppresses pointer vibration caused by load fluctuations or mechanical shock, ensuring steady and reliable indication under dynamic operating conditions.
  • Multiple CT ratio options: Available in standard transformer ratios including 50/5A, 75/1A, 100/5A, 200/5A, 400/5A, 600/5A, 1000/5A and 2000/5A to match system requirements.
  • Robust industrial housing: Flame-retardant ABS engineering plastic case with scratch-resistant transparent cover, suitable for long-term operation in indoor electrical panel environments.
  • Standard panel mount footprint: Universal 80×80mm form factor with 76×76mm cutout, enabling direct replacement for all standard 6L2-format ammeters.
  • Straightforward installation: Complete with rear mounting brackets and fixing screws, requiring no specialized tools for flush panel installation.

Detailed Technical Specifications

ParameterSpecification Details
Model Series6L2 Series
Operating PrincipleMoving-coil magnetic system, analog pointer indication
Measured QuantityAlternating Current (AC)
Total Current Range30A ~ 2000A (2KA) full coverage
Standard Rated Current Options30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 600A, 800A, 1000A, 1500A, 2000A
Common CT Ratios50/5A, 75/5A, 75/1A, 100/5A, 150/5A, 200/5A, 300/5A, 400/5A, 600/5A, 1000/5A, 2000/5A
Accuracy ClassClass 1.5
Rated Frequency50Hz / 60Hz
Front Panel Size80mm × 80mm
Panel Cutout Size76mm × 76mm (standard)
Mounting MethodFlush / embedded panel mount
Housing MaterialFlame-retardant ABS engineering plastic
Dial CoverScratch-resistant transparent plastic
Connection TypeDirect series connection (≤50A); CT secondary connection (>50A)
Operating Temperature Range-20°C ~ +50°C
Storage Temperature-30°C ~ +60°C
Relative Humidity≤85% RH, non-condensing
Front Protection DegreeIP40
ComplianceConforms to GB/T 7676 and relevant industrial standards

Application Scenarios

  • Low-voltage switchgear & MCC panels: Main feeder and branch circuit current monitoring in motor control centers and power distribution units.
  • Distribution cabinets & power panels: Real-time load current indication in factory and building electrical rooms.
  • Generator set control panels: Output current monitoring for diesel generators, standby power systems and small power stations.
  • Industrial machinery control panels: Motor load current indication on production equipment, pump and fan control panels.
  • Electrical test benches & laboratory setups: Current measurement for testing, calibration and educational electrical systems.
  • Capacitor bank & compensation panels: Current monitoring for power factor correction equipment.
  • Commercial & building electrical rooms: Load current monitoring in offices, malls, hospitals and public facilities.
  • Renewable energy systems: AC side current indication in solar photovoltaic, wind power and energy storage distribution units.

Selection Guide

  1. Determine rated current: Select a meter with a full-scale rating slightly higher than the maximum operating current of the circuit.
  2. Choose connection method:
    • For circuits ≤50A: direct-connection ammeter models are available.
    • For circuits >50A: select an ammeter with a current transformer ratio matching your CT specification (e.g. 200/5A meter paired with 200/5A CT).
  3. Confirm CT secondary rating: Standard options are 5A secondary or 1A secondary; ensure the meter matches your CT output.
  4. Verify panel dimensions: Ensure your panel has a 76×76mm mounting opening compatible with the 6L2 form factor.
  5. Custom requirements: Custom dial scales, special CT ratios and OEM logo printing are available for volume orders.

Installation & Maintenance Instructions

Installation

  1. Fully de-energize the target circuit and confirm zero voltage before starting any wiring work.
  2. Insert the ammeter into the pre-cut panel opening from the front side.
  3. Secure the meter from the rear using the supplied mounting brackets and fixing screws.
  4. For direct-connection models: connect the meter in series with the measured circuit.
  5. For CT-operated models: connect the meter terminals to the current transformer secondary circuit. Critical safety note: never leave the CT secondary circuit open while the primary circuit is energized.
  6. Restore power and verify normal pointer deflection against expected load values.

Maintenance

  1. Clean the dial cover periodically with a soft, dry cloth to maintain clear visibility.
  2. Inspect terminal connections regularly for tightness and signs of overheating or corrosion.
  3. For CT-operated installations, periodically verify CT secondary circuit integrity and grounding.
  4. Avoid prolonged exposure to direct sunlight, high humidity, excessive dust or corrosive atmospheres.
  5. Recalibration every 2–3 years is recommended to maintain measurement accuracy, especially for high-current and critical monitoring applications.
  6. All electrical installation and maintenance work must be performed by qualified personnel in compliance with local electrical safety regulations.

Packaging & Ordering Information

  • Individual packaging: Single unit in inner carton with shock-absorbing foam cushioning
  • Bulk packaging: 50 pieces per standard export carton
  • Customization options: OEM logo printing, custom dial scales, special CT ratios available for bulk orders
  • Sample policy: Sample orders accepted for quality evaluation and specification verification
  • Lead time: 3–7 working days for standard specifications; 10–15 working days for custom models
  • Pricing: Volume-based tiered pricing available for wholesale, OEM and project orders

Frequently Asked Questions (FAQ)

Q: Can the 6L2 ammeter measure DC current?

A: No. The standard 6L2 ammeter is designed exclusively for alternating current (AC) systems. DC-specific variants with different internal structures are available as separate product models.

Q: Do I need a current transformer for a 50A 6L2 ammeter?

A: 50A and lower ratings can be supplied as direct-connection models. For all current ratings above 50A, a matching current transformer (CT) is required. The meter dial is scaled to correspond with the CT secondary output (typically 5A or 1A).

Q: What does accuracy class 1.5 mean?

A: Class 1.5 indicates a maximum permissible measurement error of ±1.5% of the full-scale value, which meets the standard requirements for general industrial monitoring and indication applications.

Q: What is the mounting hole size for the 6L2 ammeter?

A: The standard panel cutout dimension is 76mm × 76mm, with an overall front bezel size of 80mm × 80mm, compatible with all standard 6L2-format panel openings.

Q: What is the difference between 5A secondary and 1A secondary ammeters?

A: These refer to the rated secondary current of the matching current transformer. 5A secondary is the most common industry standard, while 1A secondary is often used for longer wiring distances or specific system designs. The meter must match the CT secondary rating.

Q: Can this meter be used outdoors?

A: The standard 6L2 ammeter has an IP40 front protection rating and is intended for indoor use inside enclosed electrical panels. Outdoor installation requires an additional weatherproof protective enclosure.

Product Overview

The 6L2 series analog AC ammeter is a widely adopted panel-mounted measuring instrument dedicated to real-time alternating current monitoring in low-voltage power systems. Covering a comprehensive current range from 30A direct connection up to 2000A (2KA) via matched current transformers, it adapts to branch circuit monitoring as well as high-current main feeder measurement.
Built around a precision moving-coil movement with magnetic damping technology, the 6L2 ammeter delivers smooth, jitter-free pointer deflection and fast response to load fluctuations. Its universal 80×80mm front panel dimension and standard 76×76mm mounting cutout are compatible with the vast majority of electrical enclosures on the market, supporting both new installation projects and drop-in retrofit replacement of existing panel meters.
Trusted by switchgear manufacturers, electrical panel builders, system integrators and MEP contractors, the 6L2 ammeter series offers proven field reliability, cost efficiency and flexible specification options, making it a staple component in industrial, commercial and infrastructure power distribution systems.

Core Features & Advantages

  • Ultra-wide current coverage: Full range from 30A to 2000A, with direct-connection models for low currents and CT-operated models for high-current circuits.
  • High-contrast clear dial: Matte white background with bold black scale markings and major graduations, enabling fast, error-free reading even from standard operating distances.
  • Class 1.5 measurement accuracy: Calibrated precision movement with a stable permanent magnetic circuit, compliant with mainstream industrial electrical metering standards.
  • Magnetic damping structure: Effectively suppresses pointer vibration caused by load fluctuations or mechanical shock, ensuring steady and reliable indication under dynamic operating conditions.
  • Multiple CT ratio options: Available in standard transformer ratios including 50/5A, 75/1A, 100/5A, 200/5A, 400/5A, 600/5A, 1000/5A and 2000/5A to match system requirements.
  • Robust industrial housing: Flame-retardant ABS engineering plastic case with scratch-resistant transparent cover, suitable for long-term operation in indoor electrical panel environments.
  • Standard panel mount footprint: Universal 80×80mm form factor with 76×76mm cutout, enabling direct replacement for all standard 6L2-format ammeters.
  • Straightforward installation: Complete with rear mounting brackets and fixing screws, requiring no specialized tools for flush panel installation.

Detailed Technical Specifications

ParameterSpecification Details
Model Series6L2 Series
Operating PrincipleMoving-coil magnetic system, analog pointer indication
Measured QuantityAlternating Current (AC)
Total Current Range30A ~ 2000A (2KA) full coverage
Standard Rated Current Options30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 600A, 800A, 1000A, 1500A, 2000A
Common CT Ratios50/5A, 75/5A, 75/1A, 100/5A, 150/5A, 200/5A, 300/5A, 400/5A, 600/5A, 1000/5A, 2000/5A
Accuracy ClassClass 1.5
Rated Frequency50Hz / 60Hz
Front Panel Size80mm × 80mm
Panel Cutout Size76mm × 76mm (standard)
Mounting MethodFlush / embedded panel mount
Housing MaterialFlame-retardant ABS engineering plastic
Dial CoverScratch-resistant transparent plastic
Connection TypeDirect series connection (≤50A); CT secondary connection (>50A)
Operating Temperature Range-20°C ~ +50°C
Storage Temperature-30°C ~ +60°C
Relative Humidity≤85% RH, non-condensing
Front Protection DegreeIP40
ComplianceConforms to GB/T 7676 and relevant industrial standards

Application Scenarios

  • Low-voltage switchgear & MCC panels: Main feeder and branch circuit current monitoring in motor control centers and power distribution units.
  • Distribution cabinets & power panels: Real-time load current indication in factory and building electrical rooms.
  • Generator set control panels: Output current monitoring for diesel generators, standby power systems and small power stations.
  • Industrial machinery control panels: Motor load current indication on production equipment, pump and fan control panels.
  • Electrical test benches & laboratory setups: Current measurement for testing, calibration and educational electrical systems.
  • Capacitor bank & compensation panels: Current monitoring for power factor correction equipment.
  • Commercial & building electrical rooms: Load current monitoring in offices, malls, hospitals and public facilities.
  • Renewable energy systems: AC side current indication in solar photovoltaic, wind power and energy storage distribution units.

Selection Guide

  1. Determine rated current: Select a meter with a full-scale rating slightly higher than the maximum operating current of the circuit.
  2. Choose connection method:
    • For circuits ≤50A: direct-connection ammeter models are available.
    • For circuits >50A: select an ammeter with a current transformer ratio matching your CT specification (e.g. 200/5A meter paired with 200/5A CT).
  3. Confirm CT secondary rating: Standard options are 5A secondary or 1A secondary; ensure the meter matches your CT output.
  4. Verify panel dimensions: Ensure your panel has a 76×76mm mounting opening compatible with the 6L2 form factor.
  5. Custom requirements: Custom dial scales, special CT ratios and OEM logo printing are available for volume orders.

Installation & Maintenance Instructions

Installation

  1. Fully de-energize the target circuit and confirm zero voltage before starting any wiring work.
  2. Insert the ammeter into the pre-cut panel opening from the front side.
  3. Secure the meter from the rear using the supplied mounting brackets and fixing screws.
  4. For direct-connection models: connect the meter in series with the measured circuit.
  5. For CT-operated models: connect the meter terminals to the current transformer secondary circuit. Critical safety note: never leave the CT secondary circuit open while the primary circuit is energized.
  6. Restore power and verify normal pointer deflection against expected load values.

Maintenance

  1. Clean the dial cover periodically with a soft, dry cloth to maintain clear visibility.
  2. Inspect terminal connections regularly for tightness and signs of overheating or corrosion.
  3. For CT-operated installations, periodically verify CT secondary circuit integrity and grounding.
  4. Avoid prolonged exposure to direct sunlight, high humidity, excessive dust or corrosive atmospheres.
  5. Recalibration every 2–3 years is recommended to maintain measurement accuracy, especially for high-current and critical monitoring applications.
  6. All electrical installation and maintenance work must be performed by qualified personnel in compliance with local electrical safety regulations.

Packaging & Ordering Information

  • Individual packaging: Single unit in inner carton with shock-absorbing foam cushioning
  • Bulk packaging: 50 pieces per standard export carton
  • Customization options: OEM logo printing, custom dial scales, special CT ratios available for bulk orders
  • Sample policy: Sample orders accepted for quality evaluation and specification verification
  • Lead time: 3–7 working days for standard specifications; 10–15 working days for custom models
  • Pricing: Volume-based tiered pricing available for wholesale, OEM and project orders

Frequently Asked Questions (FAQ)

Q: Can the 6L2 ammeter measure DC current?

A: No. The standard 6L2 ammeter is designed exclusively for alternating current (AC) systems. DC-specific variants with different internal structures are available as separate product models.

Q: Do I need a current transformer for a 50A 6L2 ammeter?

A: 50A and lower ratings can be supplied as direct-connection models. For all current ratings above 50A, a matching current transformer (CT) is required. The meter dial is scaled to correspond with the CT secondary output (typically 5A or 1A).

Q: What does accuracy class 1.5 mean?

A: Class 1.5 indicates a maximum permissible measurement error of ±1.5% of the full-scale value, which meets the standard requirements for general industrial monitoring and indication applications.

Q: What is the mounting hole size for the 6L2 ammeter?

A: The standard panel cutout dimension is 76mm × 76mm, with an overall front bezel size of 80mm × 80mm, compatible with all standard 6L2-format panel openings.

Q: What is the difference between 5A secondary and 1A secondary ammeters?

A: These refer to the rated secondary current of the matching current transformer. 5A secondary is the most common industry standard, while 1A secondary is often used for longer wiring distances or specific system designs. The meter must match the CT secondary rating.

Q: Can this meter be used outdoors?

A: The standard 6L2 ammeter has an IP40 front protection rating and is intended for indoor use inside enclosed electrical panels. Outdoor installation requires an additional weatherproof protective enclosure.