LMV1-C40 T2 40kA 385V AC Surge Protective Device SPD
LMV1-C40 T2 40kA 385V AC Surge Protective Device SPD
LVMA LMV1-C40 is a Type 2 AC Surge Protective Device (SPD) designed for 385V low-voltage power systems. Rated at 40kA maximum discharge current (Imax) and 20kA nominal discharge current (In), this 4P SPD provides robust protection against lightning surges and transient overvoltages. With a low voltage protection level (Up ≤1.8kV), DIN rail mounting, and visual status indication, it is ideal for safeguarding sensitive electrical equipment in commercial, industrial, and residential applications.
LVMA LMV1-C40 is a Type 2 AC Surge Protective Device (SPD) designed for 385V low-voltage power systems. Rated at 40kA maximum discharge current (Imax) and 20kA nominal discharge current (In), this 4P SPD provides robust protection against lightning surges and transient overvoltages. With a low voltage protection level (Up ≤1.8kV), DIN rail mounting, and visual status indication, it is ideal for safeguarding sensitive electrical equipment in commercial, industrial, and residential applications.
1. Product Overview
2. Key Features
- Type 2 Protection: Designed for secondary surge protection in low-voltage AC distribution systems, complying with international safety standards.
- High Surge Capacity: Rated at 40kA maximum discharge current (Imax) and 20kA nominal discharge current (In) (8/20μs waveform), handling moderate to severe surge events.
- Low Protection Level: Voltage protection level (Up) ≤ 1.8kV, limiting transient overvoltages to safe levels for connected equipment.
- Wide Operating Voltage: 385V AC maximum continuous operating voltage (Uc), compatible with 380/400V three-phase power systems.
- Visual Status Indicator: Green window indicates normal operation; red window signals module failure or end-of-life for quick maintenance checks.
- Pluggable Modules: Individual modules can be replaced without removing the entire SPD from the panel, reducing downtime and maintenance costs.
- DIN Rail Mounting: Standard 35mm DIN rail design for easy installation in distribution boxes and control panels.
- Robust Construction: High-quality components ensure long service life and reliable performance in harsh environments.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Product Model | LMV1-C40 |
| Poles | 1P, 2P, 3P, 4P |
| Type | Type 2 Surge Protective Device (SPD) |
| Maximum Continuous Operating Voltage (Uc) | 385V AC |
| Nominal Discharge Current (In, 8/20μs) | 20kA |
| Maximum Discharge Current (Imax, 8/20μs) | 40kA |
| Voltage Protection Level (Up) | ≤ 1.8kV |
| Response Time | <25ns |
| Operating Temperature Range | -40°C ~ +80°C |
| Mounting Type | 35mm DIN Rail |
| Status Indicator | Visual window (Green = Normal, Red = Fault) |
| Protection Class | IP20 |
| Housing Material | Flame-retardant engineering plastic |
| Standard Compliance | IEC 61643-11 |
4. Working Principle
- Under normal operating conditions, the MOVs act as high-impedance components, allowing no current to pass through the SPD.
- When a surge or transient overvoltage occurs, the MOVs instantly switch to a low-impedance state, diverting the excess current to the ground.
- The SPD limits the residual voltage (Up) to ≤1.8kV, preventing damage to downstream electrical equipment.
- After the surge event, the MOVs return to their high-impedance state, resuming normal system operation.
5. Applications
- Commercial Buildings: Offices, shopping malls, hotels, and data centers.
- Industrial Facilities: Manufacturing plants, automation systems, and power distribution panels.
- Residential Installations: Homes, apartments, and small businesses.
- Power Distribution Systems: Low-voltage switchgear, distribution boxes, and control panels.
- Renewable Energy Systems: Solar panel installations, wind turbines, and auxiliary power systems.
6. Installation Instructions
- Mounting: Install the SPD on a standard 35mm DIN rail inside the distribution panel.
- Wiring: Connect the 3 live phases (L1, L2, L3) to the SPD’s L terminals, the neutral line to the N terminal, and the ground wire to the SPD’s ground terminal.
- Safety Check: Ensure all connections are tight and comply with local electrical codes. Verify the visual status indicator shows green before energizing the system.
- Maintenance: Periodically inspect the status indicator. If the window turns red, replace the affected module immediately.
7. Why Choose LVMA LMV1-C40 SPD?
- Cost-Effective Protection: Delivers high surge handling capacity at a competitive price point.
- Easy Maintenance: Pluggable modules reduce replacement time and service costs.
- Reliable Performance: Tested to meet international standards, ensuring consistent protection.
- Compact Design: Fits seamlessly into standard distribution panels without requiring extra space.
- Trusted Brand: LVMA is a leading manufacturer of low-voltage electrical components, known for quality and durability.
8. Technical Documents & Support
- Download the full datasheet for detailed specifications, wiring diagrams, and installation instructions.
- Contact our engineering team for custom pole configurations or OEM/ODM solutions for large-scale projects.
- Request a quote with your project details for bulk pricing, lead times, and compliance certifications.
1. Product Overview
2. Key Features
- Type 2 Protection: Designed for secondary surge protection in low-voltage AC distribution systems, complying with international safety standards.
- High Surge Capacity: Rated at 40kA maximum discharge current (Imax) and 20kA nominal discharge current (In) (8/20μs waveform), handling moderate to severe surge events.
- Low Protection Level: Voltage protection level (Up) ≤ 1.8kV, limiting transient overvoltages to safe levels for connected equipment.
- Wide Operating Voltage: 385V AC maximum continuous operating voltage (Uc), compatible with 380/400V three-phase power systems.
- Visual Status Indicator: Green window indicates normal operation; red window signals module failure or end-of-life for quick maintenance checks.
- Pluggable Modules: Individual modules can be replaced without removing the entire SPD from the panel, reducing downtime and maintenance costs.
- DIN Rail Mounting: Standard 35mm DIN rail design for easy installation in distribution boxes and control panels.
- Robust Construction: High-quality components ensure long service life and reliable performance in harsh environments.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Product Model | LMV1-C40 |
| Poles | 1P, 2P, 3P, 4P |
| Type | Type 2 Surge Protective Device (SPD) |
| Maximum Continuous Operating Voltage (Uc) | 385V AC |
| Nominal Discharge Current (In, 8/20μs) | 20kA |
| Maximum Discharge Current (Imax, 8/20μs) | 40kA |
| Voltage Protection Level (Up) | ≤ 1.8kV |
| Response Time | <25ns |
| Operating Temperature Range | -40°C ~ +80°C |
| Mounting Type | 35mm DIN Rail |
| Status Indicator | Visual window (Green = Normal, Red = Fault) |
| Protection Class | IP20 |
| Housing Material | Flame-retardant engineering plastic |
| Standard Compliance | IEC 61643-11 |
4. Working Principle
- Under normal operating conditions, the MOVs act as high-impedance components, allowing no current to pass through the SPD.
- When a surge or transient overvoltage occurs, the MOVs instantly switch to a low-impedance state, diverting the excess current to the ground.
- The SPD limits the residual voltage (Up) to ≤1.8kV, preventing damage to downstream electrical equipment.
- After the surge event, the MOVs return to their high-impedance state, resuming normal system operation.
5. Applications
- Commercial Buildings: Offices, shopping malls, hotels, and data centers.
- Industrial Facilities: Manufacturing plants, automation systems, and power distribution panels.
- Residential Installations: Homes, apartments, and small businesses.
- Power Distribution Systems: Low-voltage switchgear, distribution boxes, and control panels.
- Renewable Energy Systems: Solar panel installations, wind turbines, and auxiliary power systems.
6. Installation Instructions
- Mounting: Install the SPD on a standard 35mm DIN rail inside the distribution panel.
- Wiring: Connect the 3 live phases (L1, L2, L3) to the SPD’s L terminals, the neutral line to the N terminal, and the ground wire to the SPD’s ground terminal.
- Safety Check: Ensure all connections are tight and comply with local electrical codes. Verify the visual status indicator shows green before energizing the system.
- Maintenance: Periodically inspect the status indicator. If the window turns red, replace the affected module immediately.
7. Why Choose LVMA LMV1-C40 SPD?
- Cost-Effective Protection: Delivers high surge handling capacity at a competitive price point.
- Easy Maintenance: Pluggable modules reduce replacement time and service costs.
- Reliable Performance: Tested to meet international standards, ensuring consistent protection.
- Compact Design: Fits seamlessly into standard distribution panels without requiring extra space.
- Trusted Brand: LVMA is a leading manufacturer of low-voltage electrical components, known for quality and durability.
8. Technical Documents & Support
- Download the full datasheet for detailed specifications, wiring diagrams, and installation instructions.
- Contact our engineering team for custom pole configurations or OEM/ODM solutions for large-scale projects.
- Request a quote with your project details for bulk pricing, lead times, and compliance certifications.